Selecting And Preparing Weld Output Cables; Weld Cable Size - Miller Electric GPS-500 Owner's Manual

Arc welding power source for use with a mog system
Table of Contents

Advertisement

3-4. Selecting And Preparing Weld Output Cables

Tools Needed:

3-5. Weld Cable Size*

100 ft (30 m) Or Less
Welding
10 To 60%
Amperes
Duty Cycle
100
4
150
3
200
3
250
2
300
1
350
1/0
400
1/0
500
2/0
600
3/0
700
4/0
800
4/0
900
2-2/0
1000
2-2/0
1250
2-3/0
1500
2-4/0
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of not more than 300 circular mils per ampere.
OM-266 Page 12
2
1
10 ft (3 m)
10 ft (3 m)
Total Cable (Copper) Length In Weld Circuit Not Exceeding
150 ft
(45 m)
60 Thru 100%
Duty Cycle
4
4
3
2
2
1
1
1/0
1/0
2/0
2/0
3/0
2/0
3/0
3/0
4/0
4/0
2-2/0
2-2/0
2-3/0
2-2/0
2-3/0
2-3/0
2-4/0
2-3/0
2-4/0
2-4/0
3-3/0
3-3/0
3-4/0
For Example,
2
Total Cable
Length In Weld
Circuit = 20 ft (6 m)
200 ft
250 ft
300 ft
(60 m)
(70 m)
(90 m)
10 Thru 100% Duty Cycle
3
2
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
2-2/0
4/0
2-2/0
2-2/0
2-3/0
2-3/0
2-4/0
2-4/0
3-3/0
2-4/0
3-4/0
3-3/0
3-4/0
3-3/0
4-3/0
4-3/0
4-4/0
4-4/0
1
Weld Output Cable
Determine total cable length in weld
circuit and maximum welding am-
peres. Use Section 3-5 to select
proper cable size.
Use shortest cables possible.
Do not use damaged cables.
2
Terminal Lug
Use lugs of proper amperage
capacity and hole size for connect-
ing to MOG terminal, and weld out-
put terminals and work connection.
sb6.1* 8/92 – Ref. S-0653
350 ft
400 ft
(105 m)
(120 m)
1
1/0
1/0
2/0
3/0
3/0
3/0
4/0
4/0
4/0
2-2/0
2-2/0
2-2/0
2-3/0
2-3/0
2-3/0
2-3/0
2-4/0
2-3/0
2-4/0
2-4/0
2-4/0
3-3/0
3-3/0
3-3/0
3-4/0
3-4/0
3-4/0
3-4/0
4-4/0
3-4/0
4-4/0
4-4/0
4-4/0
4-4/0
4-4/0
S-0007-C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gps-750

Table of Contents