Major Component Specifications - Panasonic CS-KS12NB41 & CZ-18BT1U + CU-KS12NK1A Technical & Service Manual

Dc inverter split system air conditioner
Hide thumbs Also See for CS-KS12NB41 & CZ-18BT1U + CU-KS12NK1A:
Table of Contents

Advertisement

2-2. Major Component Specifications

2-2-1. Indoor Unit
Indoor Unit (Body)
CS-KS12NB41
Control PCB
Part No.
Controls
Control Circuit Fuse
Fan
Type
Q'ty ... Dia. and Length
Fan Motor
Type
Model ... Q'ty
No. of Poles
Rough Measure RPM (Cool)
Rating
Coil Resistance
(Ambient Temp. 68 °F (20 °C))
Safety Device
Type
Over- Current Protection
Over- Heat Protection
Run Capacitor
Drain Pump
Model ... Q'ty
Rating
Coil Resistance
(Ambient Temp. 68 °F (20 °C))
Safty Device
Heat Exchanger Coil
Coil
Rows
Fins per inch
Face Area
Indoor Unit (Panel) CZ-18BT1U
Flap Motor
Type
Model ... Q'ty
Rating
Coil Resistance
(Ambient Temp. 77 °F (25 °C))
inch (mm)
Voltage / Nominal Output
Micro F
Voltage, Hz
Input
Type
Open
°F (°C)
ft
1 ... D12-5/8 / L5-3/4 (D322/L147)
Ohm
VAC
W
Ohm
Aluminum Plate Fin / Copper Tube
2
(m
2
)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Ohm
Each Pair of Terminal : 380 +/- 7%
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
17
CB-CS-KS12NB4U
Microprocessor
250V 3A
Turbo
DC Motor
SIC-62FW-D866-2 ... 1
8
470
DC160V / 23W
-
Internal Controller
Yes
Yes
-
-
PLD-12115ST-1 ... 1
AC115V, 60Hz
10.8
101 +/- 10%
Thermal Fuse
293 (145)
2
18.1
2.94 (0.273)
Stepping Motor
MP24ZN-12V ... 2
DC 12V