Download Print this page

Advertisement

Quick Links

Operating Instructions
Air Conditioner
Model No.
Indoor Unit
CS-KN9XKD-3
CS-KN12XKD-3
CS-KN18XKD-3
AVS
nanoe-G
Outdoor Unit
CU-KN9XKD-3
CU-KN12XKD-3
CU-KN18XKD-3
Operating Instructions
Air Conditioner
Before operating the unit, please read these operating
instructions thoroughly and keep them for future reference.
Before installation, the installer should:
Read the Installation Instructions, then request the customer
keep them for future reference.
Remove the remote control packed with the indoor unit.
ACXF55-31180

Advertisement

loading

Summary of Contents for Panasonic CS-KN9XKD-3

  • Page 1 Operating Instructions Air Conditioner nanoe-G Model No. Indoor Unit Outdoor Unit CS-KN9XKD-3 CU-KN9XKD-3 CS-KN12XKD-3 CU-KN12XKD-3 CS-KN18XKD-3 CU-KN18XKD-3 Operating Instructions Air Conditioner Before operating the unit, please read these operating instructions thoroughly and keep them for future reference. Before installation, the installer should: Read the Installation Instructions, then request the customer keep them for future reference.
  • Page 2 Provides maximum comfort and clean air. Use the remote control within 8 m from the remote control receiver on the indoor unit. Quick Guide Inserting the batteries Clock setting 1 Press , then press to set the time. 1 Pull out the back cover •...
  • Page 3: Table Of Contents

    Thank you for purchasing Panasonic Air Conditioner. Table of Contents Safety Precautions …… 4-11 How to Use …………………12-13 To Learn More....14 Cleaning the Air Conditioner ……………… 15 Troubleshooting ………… 16-17 Information………………… 18 Accessories • Remote control • AAA or R03 batteries × 2 •...
  • Page 4: Safety Precautions

    Safety Precautions To prevent personal injury, injury to others or property damage, please comply with the following: WARNING Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below: This appliances is not intended for accessibility by the Indoor unit and outdoor unit general public.
  • Page 5 If the supply cord is damaged, it must be replaced by the manufacturer, service agent CAUTION or similarly qualifi ed persons in order to avoid a hazard. It is strongly recommended to be installed Indoor unit and outdoor unit with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent Do not wash the indoor unit with water, electric shock or fi...
  • Page 6 Safety Precautions Must always ensure that foreign matter (oil, WARNING water, etc.) does not enter the piping. Also, when storing the piping, securely seal the opening by pinching, taping, etc. (Handling of R32 is similar to R410A.) This appliance is fi lled with R32 •...
  • Page 7 f) Precautions shall be taken to avoid 2. Servicing excessive vibration or pulsation to 2-1. Service personnel refrigerating piping. • The system is inspected, regularly supervised g) Ensure protection devices, refrigerating and maintained by a trained and certifi ed piping and fittings are well protected service personnel who is employed by the against adverse environmental effects person user or party responsible.
  • Page 8 Safety Precautions 2-3. Checking for presence of refrigerant 2-7. Checks to the refrigerating equipment • The area shall be checked with an • Where electrical components are being appropriate refrigerant detector prior to and changed, they shall be fi t for the purpose and during work, to ensure the technician is aware to the correct specifi...
  • Page 9 3. Repairs to sealed components 6. Detection of fl ammable refrigerants • During repairs to sealed components, all • Under no circumstances shall potential electrical supplies shall be disconnected from sources of ignition be used in the searching or the equipment being worked upon prior to any detection of refrigerant leaks.
  • Page 10 Safety Precautions 8. Removal and evacuation 9. Charging procedures • When breaking into the refrigerant circuit • In addition to conventional charging to make repairs – or for any other purpose procedures, the following requirements shall – conventional procedures shall be used. be followed.
  • Page 11 e) If a vacuum is not possible, make a manifold • The recovery equipment shall be in good so that refrigerant can be removed from working order with a set of instructions various parts of the system. concerning the equipment that is at hand and f) Make sure that cylinder is situated on the shall be suitable for the recovery of fl...
  • Page 12: How To Use

    How to Use To adjust airfl ow direction Upper direction AIR SWING nanoe-G Indicators Upper direction: POWER • Do not adjust the fl ap by hand. TIMER * For details operation, refer “To Learn More..” Lateral direction: nanoe-G • For lateral direction, it is manually adjustable as Lateral shown.
  • Page 13 See "To Learn More..." for details. To maximise comfort while sleeping SLEEP • This operation provides you with a comfortable environment while sleeping. It will automatically adjust the sleep pattern temperature during the activation period. • The indoor unit indicator will dim when this operation is activated. This is not applicable if the indicator brightness has been manually dimmed.
  • Page 14: To Learn More

    To Learn More... Operation mode AUTO : During operation mode selection the POWER indicator blinks. • Unit selects the operation mode according to the room temperature. • Once AUTO mode is selected, the unit will operate at the standard setting temperature. Room temperature Operation mode Standard setting temperature...
  • Page 15: Cleaning The Air Conditioner

    Cleaning the Air Conditioner Cleaning has to be carried out at regular Indoor unit intervals to ensure the unit is at optimal Aluminium fi n performance. A dirty unit may cause Front panel malfunction and you may see nanoe indicator blinks. Consult an authorised dealer. •...
  • Page 16: Troubleshooting

    Troubleshooting The following symptoms do not indicate malfunction. Symptom Cause POWER indicator blinks before the unit is • This is the preliminary step to prepare for the TIMER switched on. operation after it has been set. • When Timer is set ON, the unit may start earlier (up to 15 minutes) before the actual set time to achieve the desired temperature on time.
  • Page 17 When... ■The remote control is missing or a malfunction has occurred 1. Raise the front panel. 2. Press AUTO OFF/ON once to use in AUTO mode. 3. Press AUTO OFF/ON until you hear 1 beep, then release to use in forced COOL mode.
  • Page 18: Information

    Information Information for Users on Collection and Disposal of Old Equipment and used Batteries [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.
  • Page 19 Memo...
  • Page 20 Panasonic Corporation 1006 Kadoma, Kadoma City, Osaka, Japan Website: http://www.panasonic.com © Panasonic Corporation 2021 ACXF55-31180 Printed in Malaysia SZ0621-0...