2-2. Major Component Specifications

2-2-1. Indoor Unit
Indoor Unit (Body)
CS-KE12NB41
Control PCB
Part No.
Controls
Control Circuit Fuse
Fan
Type
Q'ty ... Dia. and Length
Fan Motor
Type
Model ... Q'ty
No. of Poles
Rough Measure RPM (Cool / Heat)
Rating
Coil Resistance
(Ambient Temp. 68 °F (20 °C))
Safety Device
Type
Over- Current Protection
Over- Heat Protection
Run Capacitor
Drain Pump
Model ... Q'ty
Rating
Coil Resistance
(Ambient Temp. 68 °F (20 °C))
Safty Device
Heat Exchanger Coil
Coil
Rows
Fins per inch
Face Area
Indoor Unit (Panel) CZ-18BT1U
Flap Motor
Type
Model ... Q'ty
Rating
Coil Resistance
(Ambient Temp. 77 °F (25 °C))
inch (mm)
Voltage / Nominal Output
Micro F
Voltage, Hz
Input
Type
Open
°F (°C)
ft
2
1 ... D12-5/8 / L5-3/4 (D322/L147)
Ohm
VAC
W
Ohm
Aluminum Plate Fin / Copper Tube
(m
2
)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Ohm
Each Pair of Terminal : 380 +/- 7%
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
13
CB-CS-KE12NB4U
Microprocessor
250V 3A
Turbo
DC Motor
SIC-62FW-D866-2 ... 1
8
470 / 520
DC160V / 23W
-
Internal Controller
Yes
Yes
-
-
PLD-12115ST-1 ... 1
AC115V, 60Hz
10.8
101 +/- 10%
Thermal Fuse
293 (145)
2
18.1
2.94 (0.273)
Stepping Motor
MPZN-12V ... 2
DC 12V