5-8. Cleaning Or Replacing Gun Liner

5/16 in
OM-1322 Page 30
Y Disconnect gun from unit first.
Head Tube
Remove nozzle, contact tip, and
adapter.
Lay gun cable out straight
before installing new liner.
Blow out gun casing.
Return To Table Of Contents
Tools Needed:
5/16 in, 10 mm
10 mm
Remove liner.
To Reassemble Gun:
Install and tighten new liner.
Cut liner off 3/4 in (20 mm) (3/8 in
[9.5 mm] for aluminum) from head
tube.
Install adapter, contact tip, and
nozzle.
Ref. ST-800 797-C