Section 5 − Maintenance &Troubleshooting; Routine Maintenance; Circuit Breaker Cb1; Unit Overload - Miller Millermatic Pulser M-15 Gun Owner's Manual

Arc welding power source and wire feeder
Hide thumbs Also See for Millermatic Pulser M-15 Gun:
Table of Contents

Advertisement

SECTION 5 − MAINTENANCE &TROUBLESHOOTING

5-1. Routine Maintenance

3 Months
Replace unreadable labels
Clean and tighten weld terminals
6 Months
Blow out or vacuum inside.

5-2. Circuit Breaker CB1

3
1

5-3. Unit Overload

Thermostats TP1 in rectifier SR1 and TP2 in stabilizer Z1 protect the unit from damage due to overheating. If TP1
and/or TP2 opens, wait several minutes before trying to weld.
Y Disconnect power
before maintaining.
Repair or replace
cracked weld cable
Remove drive roll and
carrier. Apply light coat
of oil or grease to drive
motor shaft.
OR
Return To Table Of Contents
.
Maintain more often
during severe conditions.
1
Circuit Breaker CB1
If CB1 opens, wire feeding stops.
2
Welding Gun
Check gun liner for blockage or
kinks.
3
Wire Drive Assembly
Check for jammed wire, binding
drive gear or misaligned drive rolls.
Allow cooling period and reset
breaker. Close door.
2
OM-1322 Page 27