4. Run home power supply wiring through
terminal box.
E
D
C
B
A
A. UL listed wire connectors
B. White wires
C. Black wires
D. Green (or bare) wire connected to
yellow-green wires
E. Home power supply
5. Use UL listed wire connectors and connect white wires (B)
together.
6. Use UL listed wire connectors and connect black wires (C)
together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power supply
to the 2 yellow-green ground wires (D) in terminal box using
UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Reconnect power.
" strain relief into
1. When using both upper and lower vent covers, push lower
1. For non-vented (recirculating) installations only, install
2. Install metal filters. See the "Range Hood Care" section.
3. Check the operation of the range hood blower and light. See
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Use" section.

Install Vent Covers

cover down onto hood and lift upper cover to ceiling and
install with 2 - 2.9 x 6.5 mm screws.
NOTE: For vented installations, the upper vent cover may be
reversed to hide slots.
D
C
A. Upper vent cover
B. Lower vent cover
C. 2.9 x 6.5 mm screws
D. Bracket

Complete Installation

charcoal filters over grille on blower housing. See the "Range
Hood Care" section.
the "Range Hood Use" section.
C
A
B
9