Jenn-Air 30" (76.2 CM) Installation Instructions Manual page 17

30" (76.2 cm) slide-in dual fuel downdraft ranges
Table of Contents

Advertisement

Available languages

Available languages

4-wire connection: Power Supply Cord
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
1. Feed the power supply cord through the opening in the cord/
conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
A
C
A. Terminal block
B. Ground-link screw
2. Use Phillips screwdriver to connect the green ground wire
from the power supply cord to the range with the ground-link
screw. The ground wire must be attached first.
3. Use
" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10-32 hex nuts.
A
B
C
A. 10-32 hex nut
B. Ground-link screw
C. Line 1 (black)
B
D
C. Cord/conduit plate
D. Power supply cord wires
F
E
D
D. Green ground wire
E. Neutral (center) wire
F. Line 2 (red)
4. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1 " (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges. For a 3-wire power supply cord replacement,
service kit Part Number 74011285 must be used.
6. Replace terminal block access cover.
3-wire connection: Power Supply Cord (optional)
NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1 " (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the opening in the cord/
conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
A
C
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
E
B
D
D. Power supply cord wires
E. Metal ground strap
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jds9860cdsJds9865bdpJds9860cdsJds9865bdp

Table of Contents