To handle a software upgrade failure:
Verify that the software Feature is compatible with the switch model and the correct file is used.
1.
Verify that the software Feature and the BootWare Feature are compatible. For software and
2.
BootWare compatibility, see the hardware and software compatibility matrix in the correct
Feature notes.
Check the physical ports for a loose or incorrect connection.
3.
If you are using the console port for file transfer, check the HyperTerminal settings (including the
4.
baudrate and data bits) for any wrong setting.
Check the file transfer settings:
5.
If XMODEM is used, you must set the same baudrate for the terminal as for the console port.
If TFTP is used, you must enter the same server IP addresses, file name, and working directory
as set on the TFTP server.
If FTP is used, you must enter the same FTP server IP address, source file name, working
directory, and FTP username and password as set on the FTP server.
Check the FTP or TFTP server for any incorrect setting.
6.
Check that the storage device has sufficient space for the upgrade file.
7.