Fitting The Roof Connection And Profile Rails; Setting Clearances - Worcester FKS Series Installation Instructions Manual

Flat panel solar collectors, roof mounting for worcester solar heating systems
Table of Contents

Advertisement

5

Fitting the roof connection and profile rails

5.1

Setting clearances

The dimensions given are guide values that should be
approximately maintained.
i
USER NOTE
On pan tile roofs the tile troughs
determine the true distance between the
roof hooks.
Distances of roof hooks
Every profile rail is fastened using two roof hooks
(Fig. 8). See the table for the approximate distance
between the roof hooks.
Installation
Distance w
type
portrait
approx.
1170 mm
landscape approx. 2090 mm
Tab. 5
Distance between roof hooks
i
USER NOTE
Distances x and z should always be
approximately equal to distance w.
Distances of profile rails
Set the distance between the top and bottom profile rails
(Fig. 9). Use the table values.
Installation
type
from
portrait
1320 mm
landscape
600 mm
Tab. 6
Distance (centre-centre) between bottom
and top profile rail
i
USER NOTE
Landscape installation is only possible
if roof battens are max. 420 mm apart.
6 720 613 577 (2006/04)
Distance x
Distance z
610 –
170 – 540 mm
1030 mm
1520 –
170 – 540 mm
1950 mm
Distance y
to
1710 mm
820 mm
Fitting the roof connection and profile rails
Fig. 8
Distance between roof hooks
y y
Fig. 9
Distance between profile rails
z
z
x x
63043965.11-1.SD
63043965.11-1.SD
63043965.12-1.SD
63043965.12-1.SD
15