Advertisement

Before installation
4.3

Other equipment

– Spirit level
– Plumb line
– Filling pump
– Vest harness with safety rope
– Pipe insulation
– Scaffolding
– Roofing ladder
– Crane or mobile hoist
i
USER NOTE
When fitting the roof installation set and
pipework connection, the only tool re-
quired is the size 5 Allen key from the con-
nection kit.
4.4

Transport and storage

Please ensure that the corner protectors are re-
tained. They contain pipework connection pieces
which are required for installation. All components
are protected by transport packaging.
i
USER NOTE
Dispose of the transport packaging in an
environmentally friendly recycling sys-
tem.
Transport protection for collector connections
The collector connections are protected against damage
by plastic caps.
SYSTEM DAMAGE
through damaged sealing faces.
B Do not remove the plastic caps
CAUTION!
(Fig. 5, Item 1) until immediately prior
to installation.
Storage
The collectors must be stored in dry conditions.
i
USER NOTE
Do not store collectors outside without
protection from the rain.
12
Fig. 5
Plastic caps on collector connections
1
63043965.06-1.SD
63043965.06-1.SD
6 720 613 577 (2006/04)