ECM-1 PROGRAMMABLE CONTROL - OPERATING MODES

The Doyon ECM-1 controller has two operation modes Manual and Programmable.
MANUAL: to use all functions without using recipe program.
PROGRAMMABLE: to use with recipe cook program.
Program capacity
□ Programs #1 to #99 can have up to 10 steps each (low-level programmable).
□ Program #0 is always used as the default Manual Cook mode setting (single-step).
This is the default mode when the controller powers up.
OFF MODE
Display/LED
□ Display shows OFF.
□ All other LEDs are off, except the
Press on
(start) when the oven is ON, the oven will run on preheat mode at the manual mode set
point (except if you select a cook program referred in How to Select a Cook Program or the Manual
Mode section).
To switch the oven OFF Press the RED stop button and hold it for 3 seconds. The oven will run on
cool down mode until it reaches 250°F and then switch OFF.
To change the temperature set point or timer setting press and hold for 3 sec. on
appears on the left side of the display, press on
set point or timer setting. The new set point or time setting will be automatically saved after 3 seconds.
Display/LED
□ Display scrolls current cook program name (by default MANUAL if no program yet selected).
□ 2nd line shows actual oven temperature.
□ Heat and Fan, LED follows output state.
□ Ready LED blinks.
□ Stop LED is on.
When probe temperature reaches set point, the unit beeps 5 seconds, the ready LED stays on and the
oven goes into COOK MODE.
When the oven is ON, a 3 second long press of red Stop key will go to Cool Down mode if the oven
temperature is over 250°F / 120°C before going to OFF mode. If the temperature is bellow 250°F /
120°C, the oven goes directly to the OFF mode.
DOOR SWITCH
□ If door is opened:
○ Display scrolls DOOR OPEN.
○ All outputs are turned off (unless in Cool Down mode, then fan remains on).
○ All timers pause until the door is closed.
□ When the door is closed, a short delay must expire before all accessories resume normal
operation.
Start key LED.
/