MULTIQUIP GAC-6HZR Operation And Parts Manual page 29

Portable generator honda gx340 gasoline engine
Table of Contents

Advertisement

symptom
Weak in power.
Compression is proper
but misfires.
Engine overheats.
Rotational speed
fluctuates.
Recoil starter
malfunction.
gaC6HZR 60 HZ geNeRaTOR • OpeRaTiON aNd paRTs maNual — Rev. #1 (03/31/10) — page 29
Table 6. engine Troubleshooting (Continued)
possible Cause
Water in fuel system?
Dirty spark plug?
Ignition coil defective?
Spark plug heat value improper?
Incorrect type of fuel?
Cooling fins dirty?
Governor adjusted correctly?
Governor spring defective?
Fuel flow restricted?
Recoil mechanism clogged with dust and
dirt?
Spiral spring loose?
trOublesHOOting (engine)
solution
Flush fuel system and replace with correct
type of fuel.
Clean or replace spark plug
Replace ignition coil.
Replace with correct type of spark plug.
Replace with correct type of fuel.
Clean cooling fins.
Adjust governor
Replace governor spring.
Check entire fuel system for leaks or clogs.
Clean recoil assembly with soap and water.
Replace spiral spring.

Advertisement

Table of Contents
loading

Table of Contents