Installation - MULTIQUIP GAC2.2H Operation And Parts Manual

Honda gx160 gasoline engine
Table of Contents

Advertisement

cONNecTiNg THe gROuNd
The nut and ground terminal on the generators should
always be used to connect the generators to a suitable
ground. The ground cable should be #8 size wire
minimum.
At the generator, connect the terminal of the ground cable
between the lock washer and the nut (Figure 2) and tighten
the nut fully. Connect the other end of the ground cable to
a suitable earth ground (ground rod).
GENERATOR
GROUND LUG
page 14 — gac2.2H 60 Hz geNeRaTOR• OpeRaTiON aNd paRTs maNual — Rev. #1 (03/31/10)
GAC-2.2H
120V
15A
POWERED by
Honda Engines
AC VOLTMETER
VOLTOMETRE CA
211052
GR PRISE DE
TERRE
GROUND
CABLE
#8 MINIMUM
REFERENCE
NEC 250-52(C)
Figure 2. Generator Grounding
NEUTRAL BONDED TO FRAME
V
120
NEUTRE MIS A LA MASSE A
LA CARCASSE DU MOTEUR
AC CIRCUIT BREAKER
INTERRUPTEUR DE
COURANT PRINCIPAL
A21210011
GROUND ROD
FOR EARTH
GROUND
8 FT. MINIMUM

installatiOn

CONNECT TO
BUILDING
GROUND
IF REQUIRED