Mitsubishi Electric MSZ-GA35VA Service Manual page 23

Split-type, heat pump air conditioners
Hide thumbs Also See for MSZ-GA35VA:
Table of Contents

Advertisement

9-7. Test point diagram and voltage
MSZ-GA22VA -
E1
Indoor electronic control P.C. board
Release of Auto restart
function
Solder the Jumper wire
to JR07.
(Refer to 8-3.)
Power monitor
receiver P.C.
board.
Emergency
operation switch
MSZ-GA25VA -
E1
Varistor (NR11)
SW P.C. board
MSZ-GA35VA -
E1
Power supply input
230V AC
12V DC
Indoor coil thermistor [RT12 (MAIN), RT13 (SUB)]
Room temperature thermistor (RT11)
23
Fuse(F11)
Indoor fan motor
(CN211)
1311V DC
3(-) Fiducial terminal of
cathode side on measur-
ing high-voltage DC
415V DC
5(+)3-6V DC
6(+)0V DC or 15V DC
Interlock switch(Fan)
(CN1R1)
5V DC
Indoor coil thermistor
RT12(MAIN) 12
RT13(SUB) 34
(CN112)
Horizontal vane
motor(CN151)
Room temperature
thermistor(RT11)
}
Timer short mode
point JPG, JPS
(Refer to 8-1.)
Temperature (:)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msz-ga25vaMsz-ga22vaMsz-ga25vaMsz-ga22va

Table of Contents