Download Print this page

Technical Specifications - HP ProLiant DL360p Specification

Hp proliant dl360p generation 8 (gen8)
Hide thumbs Also See for ProLiant DL360p:

Advertisement

QuickSpecs

Technical Specifications

System Unit
Dimensions (H x W x D)
Weight (approximate)
Input Requirements
(per power supply)
BTU Rating
Power Supply Output
(per power supply)
System Inlet
Temperature
Relative Humidity
(non-condensing)
Altitude
DA - 14211 Worldwide — Version 47 — December 13, 2013
HP ProLiant DL360p Generation 8 (Gen8)
8 SFF and 10 SFF
4 LFF
Maximum
(all hard drives, power
supply, and processor
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Maximum
Rated Steady-State Power 460 W (at 100 to 120 VAC),
Maximum Peak Power
Operating
Non-operating
Operating
Non-operating
Operating
Non-operating
1.7 x 17.1 x 27.5 inches (4.32 x 43.47 x 69.85 cm)
1.7 x 17.1 x 29.5 inches (4.32 x 43.47 x 74.67 cm)
8 SFF
42.3 lb (19.2 kg)
10 SFF
42.3 lb (19.2 kg)
4 LFF
45.6 lb (20.7 kg)
32 lb (14.51 kg)
100 to 120 VAC
200 to 240 VAC
4.5 Amps (at 120VAC) to 2.2 Amps (at 240 VAC)
50 to 60 Hz
1773 BTU / hr (at 120 VAC), 1715 (at 240 VAC)
460 W (at 200 to 240 VAC)
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3048 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
3048 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Page 67

Advertisement

loading

This manual is also suitable for:

Proliant dl360p generation 8Proliant dl360p gen8