System Specifications - HP SL2500 Specification

Hp sl2500 scalable system
Table of Contents

Advertisement

QuickSpecs

System Specifications

Power
ProLiant SL210tGen8 Fully Configured
Fully Loaded System Input Wattage (W)
Fully Loaded System Input Current (A rms)
Fully Loaded System Thermal (BTU- Hr)
Fully Loaded System VA (Volt-Amp)
System Leakage with all power supplies loaded (mA)
System Inrush Current with all power supplies
loaded (A)
Power cord requirements
NOTE: Power shown is for a fully configured system consisting of (2) CPUs, (16) DIMMs, (2) HDDs, and (1) PCI card per node.
Power Cord
Server Power Cords
One 6' Highline (IEC-IEC) power cord ships standard
NOTE: ProLiant SL servers are primarily connected to PDU's in data center racks so they ship standard with
only a PDU power cord (416151-B21).
NOTE: If customers require a power cord, they can check the power cord matrix for the appropriate cord.
Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix.
DA - 14656 North America — Version 6 — December 9, 2013
HP SL2500 Scalable System
115V/60Hz
651
5.7
2218
657
1.58
19
Nema 5-15P to IEC320-C13
220V/50Hz
638
3.0
2174
657
3.03
37
IEC320-C13 to IEC320-C14