Panasonic EX-F70 SERIES Ordering Manual page 4

Leak detection sensor amplifier built-in
Hide thumbs Also See for EX-F70 SERIES:
Table of Contents

Advertisement

SPECIFICATIONS
Simple wire-saving unit
Designation
Item
Model No.
Applicable connector
Supply voltage
Current consumption
Output
Utilization category
Output operation
Response time
Input No.
Normal
Error
Red LED × 8 (light up when the leak liquid is detected by a sensor connected to each channel or a sensor is mounted improperly)
Output
Pollution degree
Ambient temperature
Ambient humidity
Material
Cable
Cable extension
Weight
Accessories
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C
2) Even with only one leak detection sensor connected, an OFF signal is output if the sensor detects liquid leakage, or if the unit has been installed
incorrectly.
Leak Detection Sensor
Simple wire-saving unit for leak detection sensor
12 to 24 V DC ±10 % Ripple P-P 10 % or less
135 mA or less (including the sensor input current when all outputs of sensors are ON)
Relay contact 1a
• Switching capacity: 30 V 1 A DC (resistive load)
• Min. applied load: 10 mV 10 µA DC
• Electrical lifetime: 100,000 switching operations or more (rated load, switching frequency 20 operations/min.)
• Mechanical lifetime: 50 million switching operations or more (switching frequency 180 operations/min.)
The output relay is ON when the input signal from the sensor is ON (Note 2)
5 ms or less (excluding the response time of the sensor)
Green LED × 8 (light up when the sensor is connected to each channel and the connection setting switch is set to ON)
Orange LED [lights up when the output relay is ON (normal)]
–10 to +60 °C
+14 to +140 °F
(No dew condensation or icing allowed), Storage: –20 to +70 °C
Enclosure: ABS, Unit mounting base: POM, Terminal part: PBT
0.2 mm
Extension up to total less than 10 m
SL-CP1 (Snap male connector): 8 pcs., MS-SL-2 (Unit mounting base): 1 pc., SC-PK (Connector end cap) : 8 pcs.
EX-F70
SERIES
EX-FC1
SL-CP1
50 mA or less (for the unit itself),
DC-12 or DC-13
8 Nos.
3 (Industrial environment)
35 to 85 % RH, Storage: 35 to 85 % RH
4-core cabtyre cable, 2 m
6.562 ft
2
32.808 ft
is possible, with 0.3 mm
Net weight: 85 g approx.
EX-F60
SERIES
–4 to +158 °F
long
, or more, cable.
2
+68
°F.
856
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Wafer
Detection
Liquid Leak
Detection
Liquid Level
Detection
Water
Detection
Color Mark
Detection
Hot Melt Glue
Detection
Ultrasonic
Small / Slim
Object Detection
Obstacle
Detection
Other
Products
SQ4
EX-F70/
EX-F60

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents