SETUp & TESTINg

EQUIpMENT TYpE SElECTION SwITCH (Sw1)

This thermostat has the option of being used in heat
pump or heat/cool systems. Switch SW1 located on the
back of the thermostat's face is used to select this option.
This setting can also be checked in the Installer System
Settings under Equipment Type .
Note: Thermostat reboots within 10 seconds after switch
position is changed .

INSTAllER SETUp MENU

HOw TO ENTER THE INSTAllER SETUp MENU TO CHANgE SYSTEM SETTINgS:
press [MODE] to set system to OFF .
press [MENU] to enter main menu .
press and hold [SETUp] for seven seconds, [INSTAll
SETUp] appears .
press [INSTAll SETUp] to enter installer setup menu .
SETTING
DESCRIPTION
SETTING
OPTIONS
61000761A 8800 Tstat Install.indd 7
DRY CONTACT
8024
OR
A-
C
B
O
Y
Y2
SETTING
NUMBER
w = Humidifier Control
Remove jumper for dry
contact control .
Y = Dehumidifier Control
Use Aprilaire Model 8024
relay card or equivalent for
dry contact control .
G
RC R W2
W
L
S2
HC
HP
HC
HP
press [NEXT] or [bACK] to page through the settings .
press
or
to adjust the setting.
press [DONE] to save and exit, or [CANCEl] to exit
without saving.
The thermostat will discard changes and exit if nothing
is pressed within 60 seconds .
To reset the installer settings to the default, reset the
thermostat by pressing the [RESET] key .
SUPPORT
MODULE
S1 T1 T2
RSB RSA
Sw1
HEAT/COOL
HEAT PUMP
3/28/11 3:25:16 PM