Three-Conductor Branch Circuit Connection - GE TRIVECTION JT930 Installation Instructions Manual

30” built-in wall oven
Hide thumbs Also See for TRIVECTION JT930:
Table of Contents

Advertisement

THREE-CONDUCTOR BRANCH
8
CIRCUIT CONNECTION
When connecting to a three-conductor branch
circuit, if local codes permit:
A
Connect the bare oven ground conductor
with the crimped neutral (white) lead to
the branch circuit neutral (white or gray
in color), using a wire nut.
B
Connect the oven red lead to the branch
circuit red lead in accordance with local
codes, using a wire nut.
Connect the oven black lead to the
C
branch circuit black lead in accordance
with local codes, using a wire nut. If the
residence red, black or white leads are
aluminum conductors, see WARNING
under ATTENTION INSTALLER.
Install Junction Box Cover.
D
Installation Instructions
Ground and
Neutral Wires
Junction Box Cover
11