34
en | Installing the Monitor
2.
3.
4.
5.
6.
7.
8.
F.01U.172.600 | 1.0 | 2010.10
Configure the following settings for the Dinion camera:
VMD: OSD
Area: 1
Active: On
Connect one flying lead to relay output three (3), on the
back of the Dinion camera, and connect the other to relay
output four (4).
Connect the other end of the Trigger cable to the Trigger
Input connector on the bottom panel of the monitor.
Plug the monitor into a power socket; then press the
Power button.
On the monitor, access the Trigger menu:
a.
Press the Menu button.
b.
Press the Down Arrow button to access the Setup
menu.
c.
Press the Right Arrow button to enter the Setup
menu.
d.
Press the Down Arrow button until Trigger is
highlighted; then press the Right Arrow button.
Make the necessary changes to the Trigger menu so that
the settings match the following:
Trigger Enable
Trigger Input
Buzzer
Trigger Time
Trigger Option
Move
Press the Menu button three (3) times to exit the menu
and to return to the video display.
User's Manual
Full HD LCD Monitors
On
AV1
On
10
High
Enter
Enter
Bosch Security Systems, Inc.
Exit