Aux 1 2x Doubler Function 6.3.2 Aux 2 Wiper Function 6.3.3 Aux 3 Illuminator Control 6.3.4 Aux 4 Iris Control 6.3.5 Aux 5 Lens IR Correction Mode 6.3.6 Aux 6 Camera Color/Mono Mode Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11...
Page 4
Aux 4 Iris Control 6.6.5 Aux 5 Lens IR Correction Mode 6.6.6 Aux 6 Camera Color/Mono Mode 6.6.7 Aux 7 ZX700 IR On/Off Control 6.6.8 Aux 8 SLED IR On/Off Control F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc.
THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN READILY ACCESSIBLE. A CLASS 1 APPARATUS SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A PROTECTIVE EARTHING CONNECTION Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11...
Disposal - Your Bosch product was developed and manufactured with high-quality material and components that can be recycled and reused. This symbol means that electronic and electrical appliances, which have reached the end of their working life, must be collected and disposed of separately from household waste material.
Page 8
The system ground is only used to comply with safety standards or installation practices in certain countries. Bosch does not recommend connecting system ground to safety ground unless it is explicitly required. However, if the system ground and safety ground are connected and grounding loops are causing interference in the video signal, use an isolation transformer (available separately from Bosch).
Page 9
Global View Station 1000 Safety | en Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of lost digital information, Bosch Security Systems recommends multiple, redundant recording systems, and a procedure to back up all analog and digital information.
Page 10
Cette brochure est disponible auprès du U.S. Government Printing Office, Washington, DC 20402, États-Unis, sous la référence n° 004-000-00345-4. Copyright This manual is the intellectual property of Bosch Security Systems and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Global View Station 1000 Safety | en Customer Support and Service If this unit needs service, contact the nearest Bosch Security Systems Service Center for authorization to return and shipping instructions. Service Centers Repair Center- Telephone: 800-566-2283 Fax: 800-366-1329 E-mail: repair@us.bosch.com...
Doing so may cause the system to malfunction and the unit may stall when the preset is called, either manually or in a tour function. F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc.
Preset tours allow the system to automatically pan, tilt, zoom, and focus to preset positions already defined in the system for a defined period of time. For the GVS1000, the system is capable of storing up to three separate preset tours. To program a preset tour, perform the following steps: –...
Aux2 ON or Call preset 52: wiper on Aux2 OFF or Call preset 62: wiper off Default: wiper off When wiper is activated, it will remain on until the deactivate command is given. F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc.
Page 15
Aux5 OFF or Call preset 65: IR-corrected mode off Default: IR-corrected mode off The setting of the lens mode is crucial to ensure optimal performance of the GVS1000 system. In day operation, the IR-corrected mode will not be needed. In dark environments where the majority of light on scene is provided by the IR illuminators, the lens should be set to IR- corrected mode.
Page 16
The SLED illuminators are wider angle short to medium range units using 3D diffuser and Constant Light illumination technology. These illuminators are useful for ensuring consistent illumination for short to medium range viewing. F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc.
The code translator unit, with the auxiliary and camera control boards act as receivers for the GVS1000 unit. During operation, LED indicators on the code translator unit can help to show when data traffic is being received by the unit, as well as if there is a detected error in the translator unit.
Pelco P/D code translator and the Biphase translator unit (item 1, below). The Biphase translator has four status LEDs, but only two are operational. Figure 3.2 Location of Biphase code Translator inside GVS1000 Power Supply Unit During normal operation, the Rx and Tx lights flash when valid communication with the correct address is received by the code translator box.
The Installer Menu setting is accessed by pressing the Menu/Select key for at least 1 second. Figure 4.1 OSD keypad location on camera Figure 4.2 OSD keypad detail, showing back-focus lock Left Key Up Key Menu/Select Key Right Key Down Key Lock Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11...
Page 20
IR Contrast Normal Color Burst Enhance/Dynamic Engine XF-Dynamic XF-DYN Autoblack Black Level Sharpness Auto Peak White Invert Color White Balance Speed Medium Red Gain Blue Gain Green Gain Saturation F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc.
Page 21
Installer Menu The table below shows the Installer Menu default camera settings for the camera. Submenu Function Value Lens Wizard Lens Type Video Alarm I/O Alarm I/P Alarm Action Mono Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11...
Fuzzy image Verify that the housing front glass is clean. The GVS1000 is equipped with a wiper (controlled through Aux 2). The image may be out of focus. Focus the image using the controlling device.
Troubleshooting with Diagnostic Mode In the auxiliary control board, change DIP1, Switch 6 to ON. The GVS1000 diagnostics mode is now active. The GVS1000 will cycle through all its auxiliaries and activating the appropriate LEDs corresponding to the auxiliaries.
Install the PTCR-20 Remote Emulator using the supplied CD. Connect the GVS1000 to the PC using an RS232 straight cable. Unplug the green terminal blocks from the code translator in the PSU. If the green terminal blocks are not removed from the code translator when RS232 cable is attached, the software control may not function properly.
Page 25
Figure 6.4 PTCR-20 Main Screen with Handshake After testing and setup, exit PTCR-20, disconnect the RS232 cable, and reconnect the green terminal blocks in the PSU. Contact a Bosch service centre for further instructions as needed. Bosch Security Systems, Inc.
Then, click the Set Up Soft Limit to set the Up Soft Limit. Repeat for the Clockwise, Counter Clockwise, and Down Soft Limits. NOTICE! Disengage the SL Override before exiting the software. F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc.
Page 27
In the dial feedback, only the inner colored donut/circle is of interest. Red denotes an out of bounds area (a limit) and green denotes a free moving area. Figure 6.9 Feedback Dials Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11...
6.1.4 Other Menus The MOVE TO menu allows the user to input a coordinate for the GVS1000 to move to, the PRESETS menu allows the user to manage the preset positions, the TOURS menu allows the user to use to compose a tour from preset positions, and the OFFSETS menu allows the user to set or reset the coordinate system for the GVS1000.
– Address MUST be the same for Auxiliary Control board (in PSU), Camera Control board (in camera assembly), and Code Translator (in PSU) – See the GVS1000 Installation Manual for further details 6.2.3 Protocol Selection – For Biphase models, ensure Pelco D mode is enabled.
LED11 – indicates power input to SLED control boards – Default: LED11 on (showing power available for SLED) – CN4 – relay connection to two SLED control boards – T3 – power input to current control board Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11...
LED15 ON = power output to SLED #2 on – LED15 OFF = power output to SLED #2 off – Default: LED15 off (power to SLED #2 off) – Voltage should read 15 VDC ± 0.7 VDC F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc.
Switches 1-4 for system address setting; switch 5 for Pelco P/D selection; switch 6 for diagnostics function on/off control DIP2 IR correction controls (positions 1 and 2 should be ALWAYS OFF - DEFAULT) Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11...
No Aux7 indicator present on this board, only on Auxiliary Control board. 6.6.8 Aux 8 SLED IR On/Off Control – No Aux8 indicator present on this board, only on Auxiliary Control board. Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11...
Page 36
| Test Software Global View Station 1000 F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc.