en | Subsystem Maintenance and Upgrading
To replace a cooling module, please follow these instructions:
1.
Fig. 6.10 Removing the Cooling Module
2.
3.
6.7

Replacing a Failed Hard Drive

Hard drives for the subsystem can be purchased separately. When purchasing the hard drives,
the following factors should be considered:
Capacity (MB/GB): Use drives with the same capacity. RAID arrays use a "least-common-
denominator" approach. The maximum capacity of each drive used in the array is the maxi-
mum capacity of the smallest drive. Choose big drives with the same storage capacity.
Profile: The drive trays and bays of the system are designed for 3.5-inch wide x 1-inch-high
hard drives. It is highly recommended that you do not try to use drives of any other size.
Drive type: The RAID subsystem described in this manual can use SATA-I or SATA-II hard
drives. Please ensure that you purchase the correct hard drives.
CAUTION!
6.7.1

Hard Drive Maintenance Overview

F.01U.027.798 | V1 | 2006.06
Remove the cooling module. Two (2) clips secure the cooling module to the subsystem. To
remove the cooling module push these clips together and gently pull the cooling module
out of the enclosure. (See Figure 6.10)
Forcing or slamming a module into place can damage the pins on the module connectors
either on the module itself or on the connectors of system backplane.
Install the new cooling module. To do this, align the replacement cooling module with the
bay from which the faulty one was removed. Then gently slide the new cooling module
into the enclosure subsystem.
The hard drives and drive trays should only be installed into the subsystem after the sub-
system has been mounted into a rack cabinet. If the hard drives are installed first, the
subsystem will be too heavy to lift and the possible impact during installation may dam-
age your drives.
Handle hard drives with extreme care. Hard drives are very delicate. Dropping a drive
onto a hard surface (even from a short distance) and hitting or touching the circuits on
the drives with your tools may cause damage to the drives.
Observe all ESD prevention methods when installing drives.
Only use screws supplied with the drive canisters. Longer screws may damage the drive.
Hot-swappable drive trays: The drive trays are all hot-swappable. If a hard drive fails, it
can be replaced while the subsystem is still running.
Open flap: Once the flap on the drive tray has been opened, the drive tray must be
removed from the subsystem. Failure to remove the drive tray from the subsystem after
the flap has been opened may result in signal glitches and Data Compare Errors might
ensue.