Page 10
Maximum Capacity (Dry Weight) Basket Diameter Basket Depth Basket Motor Blower Motor Door Opening (Diameter) Basket Volume Dryers Per 20’/40’ Container Dryers Per 45’ /48’ Truck Voltage Available Heat Input Approx. Weight (Uncrated) Approx. Weight (Crated) Airflow Inlet Size Compressed Air Connection Compressed Air Requirement Voltage Available Approx.
Page 26
M DG-170 (Gas) M DS-170 (Steam) LECTRICAL IMPORTANT: 208 VAC 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage. NOTE: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY. B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.
Page 30
Manifold Pressure* 3.5 inches W.C. Inline Pressure 6.0 - 12.0 inches W.C. Shaded areas are stated in metric equivalents * Measured at outlet side of gas valve pressure tap when gas valve is on. kcal/hr Per Hour MODEL Rating Rating NUMBER MDG-170 550,000...
Page 33
PERATING AXIMUM INIMUM (Normal Load) NPUT (Approximate) @ 125 ONSUMPTION Shaded areas are stated in metric equivalents * Minimum operating pressure for optimium results. TEAM RESSURE 125 psig 100 psig* 19 Bhp lbs/hr 862 kPa 689 kPa 329.1 kg/hr...
Page 35
OMPRESSED UPPLY Normal Minimum Supply Maximum Supply Shaded areas are stated in metric equivalents RESSURE 80 PSI 552 kPa 70 PSI 483 kPa 90 PSI 621 kPa...
Page 41
OMPRESSED UPPLY Normal Minimum Supply Maximum Supply Shaded areas are stated in metric equivalents RESSURE 80 PSI 552 kPa 70 PSI 483 kPa 90 PSI 621 kPa...
Page 64
Timing Legend Spin Time Switch Position Number Time in Seconds* Dwell (Stop) Time Switch Position Number Time in Seconds* * Values shown are +/- 1 second.
Page 70
I M P O R T A N T MANUAL RESET HI-LIMIT INSTRUCTIONS FOR DUAL TIMER OR PHASE 5 WITHOUT HEAT FAULT (GAS MODELS ONLY) This dryer is equipped with a burner hi-limit and tumbler/lint chamber hi-limit thermostat which must be reset manually. Discontinue power to dryer before attempting to reset hi-limit.
Page 71
I M P O R T A N T MANUAL RESET HI-LIMIT INSTRUCTIONS FOR DUAL TIMER OR PHASE 5 WITHOUT HEAT FAULT (STEAM MODELS ONLY) This dryer is equipped with a lint chamber hi-limit thermostat which must be reset manually Discontinue power to dryer before attempting to reset hi-limit.