MAINTENANCE AND TROUBLESHOOTING

Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap. IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not turn on, make sure that the
power cord is fully plugged in. If lines appear in the
console display, see HOW TO CHANGE CONSOLE
SETTINGS on page 22 and adjust the contrast level
of the display.
If the handgrip heart rate monitor does not function
properly, see step 5 on page 19.
HOW TO CALIBRATE THE RAMP
If the ramp is not functioning properly, the ramp may
need to be calibrated. To calibrate the ramp, press and
hold the Calories button for several seconds until the
test mode appears in the display.
Press the Calories button again. Then, press the
Power Ramp increase or decrease button to calibrate
the ramp. The ramp will move upward and downward
as it calibrates.
When the ramp stops moving, the ramp is calibrated.
Then, press the Calories button repeatedly to exit the
calibration mode.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the reed
switch, first unplug
the power cord.
Using a flat screw-
driver, release the
tabs on the Access
Cover (20) and pry
the Access Cover
upward off the
elliptical.
20
Next, look into the access opening and locate the Reed
Switch (69). Rotate the Large Pulley (74) until a Pulley
Magnet (75) is aligned with the Reed Switch.
75
106
69
Next, loosen, but do not remove, the indicated M4 x
16mm Screw (106). Slide the Reed Switch (69) slightly
toward or away from the Pulley Magnet (75). Then,
retighten the Screw.
Plug in the power cord and rotate the large pulley for
a moment. Repeat these actions until the console
displays correct feedback. When the reed switch is cor-
rectly adjusted, reattach the access cover.
23
74