Battery operating time (with backlight low)
Battery charging time
Battery power saving functions
Safety
Compliance
Environmental
Operating temperature
Storage temperature
Humidity
Maximum operating altitude
Maximum storage altitude
Electro-Magnetic-Compatibility (EMC)
Interface
Warranty
Probe calibration output
FlukeView
ScopeMeter
®
FlukeView ScopeMeter software helps you
get more out of your ScopeMeter:
• Store instrument's screen copies on the PC, in color
• Copy screen images into your reports and
documentation
• Capture and store waveform data from your
ScopeMeter on your PC
• Create and archive waveform references for
automatic or visual comparison
• Includes waveform analysis, e.g. FFT spectrum
analysis
• Copy waveform data into your spreadsheet for
detailed analysis
• Use cursors for parameter measurement
190C Series
199C, 196C, 192C, 215C, 225C,
> 3½ hours
4 hours
Auto 'power down' with adjustable
power down time.
On-screen battery power indicator.
EN61010-1-2001, Pollution Degree 2;
UL61010B, with approval;
CAN/CSA C22.2, No. 61010-1-04, with
approval; ANSI/ISA-82.02.01
0 °C ~ +50 °C
+10 °C ~ +30 °C: 95 % RH non-condensing
+30 °C ~ +40 °C: 75% RH non-condensing
+40 °C ~ +50 °C: 45% RH non-condensing
3,000 m (10,000 feet)
EN 61326-1 for emission and immunity
Optical port in instrument transfers
instrument settings, screen images and
waveform data, compatible with FlukeView®
software for Windows®, via optional OC4USB
or PM9080 (optical to electrical interface
cable)
Three-years (parts and labor) on main instrument, one-year on accessories
(through DMM-input banana connectors)
Software
®
System requirements
• Microsoft
®
• CD-ROM drive
• One free USB port
Supported Instruments
With the new release V5, the following typenumbers
are supported:
• Fluke 190C-series (225C, 215C, 199C, 196C, 192C,
using an OC4USB or PM9080 interface cable);
• Fluke 190B-series (199B, 196B, 192B, using an
OC4USB or PM9080 interface cable);
• 190-series II (190-204 and 190-104, using
USB-cable);
• 120-series (123, 124, 125, using an OC4USB or
PM9080 interface cable).
190-204, 190-104
Up to 7 hours using BP291 (included)
Auto 'power down' with adjustable
power down time; Auto 'Display off' with
adjustable power down time; On-screen
battery power indicator.
EN61010-1-2001, Pollution Degree 2;
CAN/CSA C22.2, No. 61010-1-04, with
approval; UL61010B; ANSI/ISA-82.02.01
0 °C ~ +40 °C incl. battery
+40 °C ~ +50 °C excl. battery
-20 °C ~ +60 °C
Up to 2,000 m (6666 ft) for CAT IV 600 V,
CAT III 1000 V; up to 3,000 m (10,000 ft) for
CAT III 600 V, CAT II 1000 V
12 km (40,000 ft)
EN 61326-1 (2005-12) for emission and
Two USB ports provided. Ports are fully
insulated from instrument's floating
measurement circuitry. USB-host port directly
connects to external flash memory drive
for storage of waveform data, measurement
results, instrument settings and screen
copies. A mini-USB-B is provided which
allows for interconnection to PC for remote
control and data transfer under PC-control.
Dedicated probe-cal output with reference
contact provided, fully insulated from any
measurement input channel
Windows
XP and beyond
®
ScopeMeter 190 Series II
190 Series II
5 hours
immunity
Fluke Corporation 7