System Requirements - Fluke 190-104 Technical Data Manual

Fluke 190-series ii 4-channel scopemeters product datasheet
Hide thumbs Also See for 190-104:
Table of Contents

Advertisement

Battery operating time (with backlight low)
Battery charging time
Battery power saving functions
Safety
Compliance
Environmental
Operating temperature
Storage temperature
Humidity
Maximum operating altitude
Maximum storage altitude
Electro-Magnetic-Compatibility (EMC)
Interface
Warranty
Probe calibration output
FlukeView
ScopeMeter
®
FlukeView ScopeMeter software helps you
get more out of your ScopeMeter:
• Store instrument's screen copies on the PC, in color
• Copy screen images into your reports and
documentation
• Capture and store waveform data from your
ScopeMeter on your PC
• Create and archive waveform references for
automatic or visual comparison
• Includes waveform analysis, e.g. FFT spectrum
analysis
• Copy waveform data into your spreadsheet for
detailed analysis
• Use cursors for parameter measurement
190C Series
199C, 196C, 192C, 215C, 225C,
> 3½ hours
4 hours
Auto 'power down' with adjustable
power down time.
On-screen battery power indicator.
EN61010-1-2001, Pollution Degree 2;
UL61010B, with approval;
CAN/CSA C22.2, No. 61010-1-04, with
approval; ANSI/ISA-82.02.01
0 °C ~ +50 °C
+10 °C ~ +30 °C: 95 % RH non-condensing
+30 °C ~ +40 °C: 75% RH non-condensing
+40 °C ~ +50 °C: 45% RH non-condensing
3,000 m (10,000 feet)
EN 61326-1 for emission and immunity
Optical port in instrument transfers
instrument settings, screen images and
waveform data, compatible with FlukeView®
software for Windows®, via optional OC4USB
or PM9080 (optical to electrical interface
cable)
Three-years (parts and labor) on main instrument, one-year on accessories
(through DMM-input banana connectors)
Software
®

System requirements

• Microsoft
®
• CD-ROM drive
• One free USB port
Supported Instruments
With the new release V5, the following typenumbers
are supported:
• Fluke 190C-series (225C, 215C, 199C, 196C, 192C,
using an OC4USB or PM9080 interface cable);
• Fluke 190B-series (199B, 196B, 192B, using an
OC4USB or PM9080 interface cable);
• 190-series II (190-204 and 190-104, using
USB-cable);
• 120-series (123, 124, 125, using an OC4USB or
PM9080 interface cable).
190-204, 190-104
Up to 7 hours using BP291 (included)
Auto 'power down' with adjustable
power down time; Auto 'Display off' with
adjustable power down time; On-screen
battery power indicator.
EN61010-1-2001, Pollution Degree 2;
CAN/CSA C22.2, No. 61010-1-04, with
approval; UL61010B; ANSI/ISA-82.02.01
0 °C ~ +40 °C incl. battery
+40 °C ~ +50 °C excl. battery
-20 °C ~ +60 °C
Up to 2,000 m (6666 ft) for CAT IV 600 V,
CAT III 1000 V; up to 3,000 m (10,000 ft) for
CAT III 600 V, CAT II 1000 V
12 km (40,000 ft)
EN 61326-1 (2005-12) for emission and
Two USB ports provided. Ports are fully
insulated from instrument's floating
measurement circuitry. USB-host port directly
connects to external flash memory drive
for storage of waveform data, measurement
results, instrument settings and screen
copies. A mini-USB-B is provided which
allows for interconnection to PC for remote
control and data transfer under PC-control.
Dedicated probe-cal output with reference
contact provided, fully insulated from any
measurement input channel
Windows
XP and beyond
®
ScopeMeter 190 Series II
190 Series II
5 hours
immunity
Fluke Corporation 7