Ac/Dc Voltage Measurement - Fluke 1503 User Manual

Insulation testers
Hide thumbs Also See for 1503:
Table of Contents

Advertisement

IP Rating..............................................................IP40
Altitude ................................................................Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Over-Range Capability ........................................110% of range
Compliance to EN 61557 ....................................IEC61557-1, IEC61557-2, IEC61557-4, IEC61557-10
Model 1503 Accessories .....................................TL224 Leads
Model 1507 Accessories .....................................TL224 Leads

AC/DC Voltage Measurement

Accuracy
Range
600.0 V
Input Impedance..................................................3 MΩ (nominal), <100 pF
Common Mode Rejection Ratio
(1 kΩ unbalanced)...............................................>60 dB at dc, 50 or 60 Hz
Overload Protection.............................................600 V rms or dc
Non Operating (Storage): 12,000 m
TP74 Probes
Clips PN 1958654 (red) and PN 1958646 (black)
Holster
TP74 Probes
Clips PN 1958654 (red) and PN 1958646 (black)
Holster
Remote Probe
Resolution
0.1 V
Insulation Testers
Specifications
50 Hz to 400 Hz
± (% of Rdg + Digits)
+ (2 % + 3)
21