Modern Compressor Display And Settings; Soft Knee / Hard Knee Compression; Modern Compressor Meters; Modern Gate At A Glance - Mackie DL806 Reference Manual

Reference guide
Hide thumbs Also See for DL806:
Table of Contents

Advertisement

Mackie DL806 and DL1608 Reference Guide

Modern Compressor Display and Settings

The compressor for each channel may be adjusted by moving the gain, threshold and ratio balls
or moving any of the five sliders left and right. Additionally, exact settings may be entered into
the current parameter display. The compressor may be adjusted whether the compressor is on or off.
The iPad channel only has a compressor, not a gate.
Threshold — Threshold sets the threshold of the compressor in dB below 0 dBFS.
The range of the threshold setting varies from –80 dBFS to 0 dBFS.
Ratio — Ratio sets the amount of gain reduction applied as the signal exceeds the threshold level.
The range of the ratio of the compressor varies from 1:1 to inf:1.
Attack — Attack determines how quickly the compressor reacts once the signal is above threshold.
Short attack times allow compressing on short transients, while longer attack times cause these transients
to be ignored. The range of the attack time varies from 0 ms to 300 ms.
Release — Release determines how long it takes for the compressor to end gain reduction once the signal
drops back below the threshold. The range of the release speed varies from 50 ms to 3 seconds.
Gain — Gain adds make-up gain to the output of the compressor. This is useful to make the
apparent volume of the signal the same with the compressor in and out of the signal chain.
The range of the make-up gain varies from 0 dB to 20 dB.

Soft Knee / Hard Knee Compression

This switch sets the shape of the gain reduction curve at the threshold level. When set to hard, the gain
reduction curve changes abruptly at the threshold level. When set to soft, the gain reduction curve changes
gently as it transitions to the final ratio amount.

Modern Compressor Meters

These three meters show the input level, amount of gain reduction and output level. The input and output
meters range from –90 dBFS to 0 dBFS. The reduction meter of the compressor ranges from 0 to 20 dB.

Modern Gate at a Glance

Parameter
Gate Enable
Threshold

Modern Compressor at a Glance

Parameter
Comp Enable
Threshold
Low Value
Off
–80 dBFS
Attack
0 ms
Release
50 ms
Range
0 dB
Hold
0 ms
Low Value
Off
–80 dBFS
Ratio
1 : 1
Gain
0 dB
Attack
0 ms
Release
50 ms
Knee
Soft
High Value
On
0 dBFS
300 ms
3 s
60 dB
5 s
High Value
On
0 dBFS
INF : 1
20 dB
300 ms
3 s
Hard
66
Default
On
–80 dBFS
0.1 ms
250 ms
60 dB
0 ms
Default
On
0 dBFS
2 : 1
0 dB
0.1 ms
250 ms
Soft

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dl1608