Important Safety Instructions; For Your Safety - GE JKP85 Installation Instructions Manual

27" built in wall oven/with microwave
Hide thumbs Also See for JKP85:
Table of Contents

Advertisement

Installation Instructions
IMPORTANT SAFETY INSTRUCTIONS
For Your Safety
• Be sure your oven is installed properly
by
a qualified
installer or service technician.
• Be sure the oven is securely
installed in a
cabinet that is firmly attached
to the house
structure.
Weight on the oven door could
cause the oven to tip and result in injury.
Never allow anyone to climb, sit, stand or
hang on the oven door.
• Make sure the cabinets
and wall cover-
ings around the oven can withstand
the
temperatures
(up to 200°F.) generated
by
the oven.
_
CAUTION: The electrical
power
to the oven supply line must be
shut off while line connections
are being made. Failure to do so
could result in serious injury or
death.
Electrical
Requirements
This appliance must be supplied with the
proper voltage and frequency, and connected
to an individual properly grounded branch
circuit, protected by a circuit breaker or fuse
having amperage as noted on rating plate.
(Rating Plate is located on oven side trim.)
We recommend
you have the electrical wiring
and hookup of your oven connected by a
qualified electrician. After installation,
have the
electrician show you where your main oven
disconnect
is located.
Check with your local utilities for electrical
codes which apply in your area. Failure to wire
your oven according to governing codes could
result in a hazardous condition. If there are no
local codes, your range must be wired and
fused to meet the requirements
of the National
Electrical Code, ANSI/NFPA
No. 70-Latest
Edition. You can get a copy by writing:
National Fire Protection Association
Battery March Park
Quincy, MA 02269
Effective January 1, 1996, the National
Electrical Code requires that new, but not
existing, construction
utilize a 4 conductor
connection
to an electric range. When
installing an electric range in new construction,
follow the instructions
in the section on NEW
CONSTRUCTION
AND FOUR CONDUCTOR
BRANCH CIRCUIT CONNECTION.
You must use a three-wire,
single-phase
A.C.
208Y/120 Volt or 240/120 Volt, 60 hertz
electrical system. If you connect to aluminum
wiring, properly installed connectors
approved
for use with aluminum wiring must be used.