Monitoring Internal Power Supplies

Command or Action
Example:
Switch# power supply 1 slot A on
Step 2
show environment power
Example:
Switch# show environment power
Monitoring Internal Power Supplies
Table 10: Show Commands for Power Supplies
Command
show environment power [ all | switch
switch_number ]

Configuration Examples for Internal Power Supplies

This example shows how to set the power supply in slot A to off:
Switch# power supply 1 slot A off
Disabling Power supply A may result in a power loss to PoE devices and/or switches ...
Continue? (yes/[no]): yes
Switch#
Jun 10 04:52:54.389: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 1 powered off
Jun 10 04:52:56.717: %PLATFORM_ENV-1-FAN_NOT_PRESENT: Fan is not present
Switch#
Catalyst 2960-XR Switch Interface and Hardware Component Configuration Guide, Cisco IOS Release 15.0(2)EX1
80
Purpose
• A —Selects the power supply in slot A.
• B —Selects power supply in slot B.
Power supply slot B is the closest to the outer edge of
Note
the switch.
• off —Set the power supply off.
• on —Set the power supply on.
By default, the switch power supply is on.
Verifies your settings.
Purpose
(Optional) Displays the status of the internal power
supplies for each switch in the stack or for the
specified switch. The range is 1 to 9, depending on
the switch member numbers in the stack.
The switch keywords are available only on
stacking-capable switches.
Configuring Internal Power Supplies