High efficiency gas-fired cast-iron boilers

Advertisement

4. WIRING AND CONNECTIONS DIAGRAMS
- Electrical connections should be performed according to the diagrams shown below.
- Connect the boiler to a single-phase, phase neutral, 230 V ~ 50 Hz power supply through a standard
terminal block or outlet with 2A max. fuses connected between the boiler and the power supply.
Remember that the boiler should always be provided with a good earth.
IMPORTANT: The manufacturer disclaims any liability for damage to property or persons caused by
failure to earth the boiler correctly.
Electrical connections diagram
TS
1
2
IC
3
4
F
1
2
3
L
N
230V ~
50Hz
Key
IC - Boiler ON/OFF switch
TA - Room thermostat
TR - Control thermostat
TF - Flue gas thermostat
VG - Gas valve
TS - Limit thermostat manual re-set
F - Thermocouple interruptor
CA - Auxiliary contact
Note: Dotted lines indicate connections to be performed during installation.
TR
TF
4
5
6
7
8
9 10
TA
CA
VG
General wiring diagram
1
3
L
230V
50Hz
TS
IC
F
2
4
N
3
Fig. 5
10
1
9
8
7
6
VG
2
4
CA
TR
TA
TF
5
9