Use & Care; Lp Tank; Lp Tank Leak Test; Lp Tank Filling - Kenmore 415.167411 Assembly Instructions Manual

Liquid propane gas grill
Table of Contents

Advertisement

LP Tank
• The LP tank used with your grill must meet the
following
requirements:
LP Tank Exchange: You may chooseto replace your empty
LP tank through an exchange service. Use only those
reputable exchange companies that inspect, precision fill,
test and certify their cylinders. Exchange for OPD safety
feature equipped tank as described in LP Tank
• PurchaseLP tanks only with these requiredmeasurements:
12" (30.5cm)(diameter)x 18" (45.7cm) (tall)with20 lb. (9
kg.) capacity maximum.
• Be constructedand marked in accordance with
specifications for LP tank of the U.S. Department of
Transportation (DOT) or for Canada, CAN/CSA-B339,
cylinders, spheres and tubes for transportation of dangerous
goods, Transport Canada (TC). See LP tank collar for
marking.
• LPtank valve musthave:
• Type 1 outlet compatiblewith regulator
or grill.
• Safety relief valve.
• UL listed Overfill Protection Device
(OPD). This OPD safety feature is
identified by a unique trfangular hand
wheel. Use only tanks equipped with this type
of valve,
OPD HandWheel
Supplysystemmustbe arrangedfor vaporwithdrawal a nd
include collar to protectLP tank valve.
LP (Liquefied
Petroleum
Gas)
• Is nontoxic, edodess and colorlesswhen produced. For
Your Safety, LP gas has been givenan odor (similarto
rotten cabbage) so that it can be smelled.
• LP gas is highly flammable and may ignite unexpectedly
when mixed with air.
• Always keep LP tank in upright positionduring use, transit or
storage.
• Leak test LP tank BEFOREconnectingto grill.
LP Tank
Leak
Test
For your safety
• Leak test must be repeated each time LP tank is exchanged
or refilled.
• Do not smoke dudng leak test.
• Do not use an open flame to check for gas leaks.
• Grill must be leak checked outdoors in well-ventilated area,
away from ignition sources such as gas fired or electrical
appliances. Dudng leak test, keep grill away from open
flames or sparks.
Use a clean paint brashand 50/50 soap and water
solution. Use mild soap and water. •
Do not use
household cleaning agents. Damage to gas train
componentscan result.
Brush soapy solution onto
the shaded areas.
LP Tank
Filling
Use only licensed and experienced dealers.
LP tank must be purged before filling.
• Dealer should NEVER fill LP tank more than 80% of LP tank
volume. Volume of propane in tank will vary by temperature.
• A frosty regulator indicates gas overfill. Immediatelyclose LP
tank valve and call local LP gas dealer for assistance.
Do not release liquidpropane (LP) gas into the atmosphere.
This is a hazardous practice.
To remove gas from LP tank, contact an LP dealer or call a
local fire department for assistance. Check the telephone
directory under "Gas companies" for nearest certified LP
dealers.
Connecting
The Regulator
To The LP Tank
1. LP tank must be properly secured onto grill. (Refer to
Assembly Section)
2. Turn all controlknobs, includingsidebumer,to the OFF
position.
3. Turn LP tank OFF by turning hand-wheel clockwiseto a full
stop,
4. Remove the protective
cap from LP tank valve.
Hand
Always use cap and
Wheel
sOapsuppliedwithvalve.
Safety Relief
with thread
Valve
on outside
4638231 • 15

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading