Maytag W10445417B Use & Care Manual page 16

Table of Contents

Advertisement

Direct Wire Connection
if your wiring looks like this:
4-wire direct connection:
Go to "4-Wire Direct Connection"
on this page.
if your wiring looks like this:
3-wire direct connection:
Go to "3-Wire Direct Connection"
on page 17.
4-Wire
Direct Wire Connection
iMPORTANT: A 4-wire connection
is required for mobile homes
and where local codes do not permit 3-wire connections.
"_,
Prepare
your 4-wire
cable
for direct
connection
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,
leaving bare ground wire at 5" (127 mm). Cut 11/2" (38 mm)
from remaining 3 wires. Strip insulation back 1" (25 mm).
Shape ends of wires into hooks.
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze
hooked ends together and tighten screws. Replace the terminal
block cover on the back of the dryer. Tighten strain relief nut.
Now, go to "Venting Requirements."
Remove the neutral ground wire (white) (F) located inside the
dryer cabinet, behind the external ground conductor screw (A).
16