iNslali_aliONiNslRUcliONs
PREPARING THE iNSTALLATiONLOCATION
IMPOR TAN T INS TA I_ LA TION INFORMATION
• All electric cooktops run off a single phase,
three-wire or four-wire cable, 240/208 volt,
60 hertz, AC-only electrical supply with ground,
• Minimum distance between cooktop and
overhead cabinetry is 30" (76,2 cm),
30" Min.
(76.2 cm)
I
Fresh a\r \ntake**
** Do not obstruct these areas!
B
C
E
D
K
4" X 8" (10.2 cm x 20.3 cm)
opening to route armored
cable if panel is present.
F
Unit
A
B
C
D
E
Min
Max
inch
3013/16
211/2
23/16
2813/16
195/8
293/8
291/2
mm
783
546
56
732.2
498
746
749
G
J
K
H
I
L
M
Min
Max
Min Max
Min
201/4
203/8
13/16
15/16
24
30
43/16
11/2
24
515
518
20
33
610
762
106
38
610
All dimensions
are stated in inches and millimeters (mm),
Allow 2" (5 cm) space below the armored cable opening to clear the electric cable and allow
space for installation of the junction box on the wall at the back of the cooktop.