Whirlpool Packaged Terminal Air Conditioner Installation Manual page 30

Packaged terminal air conditioner (ptac)/ packaged terminal pump (pthp) and accessory
Table of Contents

Advertisement

IMPORTANT: The next steps require you to make permanent
modifications
to the decorative side skirts. The modifications
are
for left and right sides, and the skirts will not be interchangeable
after modification.
NOTE: If the subbase is to be used only for structural support of
the PTAC/PTHP, you do not need to read this section on making
electrical connections.
Electrical
Shock Hazard
Disconnect
power before servicing.
Replace all parts and panels
before operating.
Failure to do so can result in death or electrical
shock.
230/208 volt power
supply
In 230/208 volt applications,
a field-supplied
NEC approved
receptacle can be installed in the subbase along with the
optional disconnect
switch accessory.
g,
1. Distance from center of holes in subbase to wall
2. Side skirt
3. Make cut on closest inside scored line to measurement.
Transfer the measurement recorded in Step 8 to each of the
side skirts.
1. Measurement
recorded in Step 8
2. Side skirts
NOTE: Round the measurement
down to the closest score
mark when transferring
the measurement.
Example: If
measurement was 7 in. (17.8 cm), use the score mark that is
at 6% in.
10. Cut the skirts along the scored marks.
11. Reattach the end brackets and side skirts to the subbase.
Adjust the side skirts until they touch the wall. Tighten the
screws.
12. Attach the end brackets to the wall sleeve with 4 - #10 x _/2 in.
screws (provided).
13. Adjust the leg bolts as needed to level the wall sleeve.
I
230/208V
I
1
r"--i
Black
u -- -- ,_.h...oT
L2
I_.
04-
White
r¢_
I
'11
/
Field Supplied
Wiring
1. Disconnect
switch (if used)
2. Field-supplied
NEC approved receptacle
3. Ground lug in subbase
230/208 volt installation
with field-supplied
NEC approved
receptacle
Parts needed
NEC approved receptacle
Green wire
1. Disconnect
power.
2. Route incoming power supply wires into the subbase behind
the front cover.
3. Connect the incoming L1 black wire to the L1 side of the
receptacle.
4. Connect the incoming L2 white or red wire to the L2 side of
the receptacle.
5. Connect the incoming green or bare ground wire to the
subbase ground lug.
6. Connect a field-supplied
green wire between the receptacle
and the subbase ground lug.
7. Reinstall the chassis into the wall sleeve, and plug power
cord into receptacle.
3O