Windsor Saber Glide SG28 Operator Instructions Manual page 17

Hide thumbs Also See for Saber Glide SG28:
Table of Contents

Advertisement

The float switch is located inside the recovery tank. The purpose of the float switch is to notify the user that
the recovery tank is full. When the float switch is activated, the scrub brush motors and solution flow will stop,
the scrub deck will raise, the squeegee will rise after 60 seconds, and the vacuum motor will turn off 10
seconds later.
The battery meter can be viewed at the left side of either information screen 1 or information screen 2. The
level of battery charge is indicated by the horizontal bars in the battery meter box. When the batteries require
charging, the icon will flash and a battery inhibit icon will appear on the right side of either information screen.
Scrub and solution functions that are running when the battery inhibit icon appears will be automatically shut
off. It is not possible to restart scrub functions while the battery inhibit is displayed. The controller reserves
enough battery charge to allow pick-up of residual water and transport back to a charging station.
8. SCRUB DECK SHIFT SWITCH (36 IN ONLY)
This switch controls the position of the retractable scrub deck. To extend the scrub deck, press and hold the
top of the switch. To retract the scrub deck, press and hold the bottom of the switch.
86037580 GLIDE 01/03/07
CONTROLS
3-10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents