GMVM96 a
d
irflow
ata
GMVM960603BX
(Rise Range: 20 - 50°F)
Adjust
CFM *
Tap
Minus(-)
855
Normal
950
Plus (+)
1,045
Minus(-)
945
Normal
1,050
Plus (+)
1,155
Minus(-)
1,053
Normal
1,170
Plus (+)
1,287
Minus(-)
1,143
Normal
1,270
Plus (+)
1,397
* @ .1" - .5" w.c. ESP
GMVM961005DX
(Rise Range: 35 - 65°F)
Adjust
CFM *
Tap
Minus(-)
1,629
Normal
1,810
Plus (+)
1,991
Minus(-)
1,665
Normal
1,850
Plus (+)
2,035
Minus(-)
1,701
Normal
1,890
Plus (+)
2,079
Minus(-)
1,746
Normal
1,940
Plus (+)
2,134
* @ .1" - .5" w.c. ESP
Notes
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• Operation is recommended below .5" w.c. ESP in heating mode. Operating CFM between .5" and .8" w.c. is tabulated for
cooling purposes only.
• High-fire CFM shown. CFM will vary proportionally with the gas valve BTU/H input.
SS-GMVM96
— H
s
eatiNG
peeds
Rise (°F)
62
56
51
56
51
46
50
45
41
46
42
38
Rise (°F)
54
49
44
53
48
43
52
47
43
51
46
41
www.goodmanmfg.com
GMVM960805CX
(Rise Range: 35 - 65°F)
Adjust
CFM *
Tap
Minus(-)
1,440
Normal
1,600
Plus (+)
1,760
Minus(-)
1,521
Normal
1,690
Plus (+)
1,859
Minus(-)
1,620
Normal
1,800
Plus (+)
1,980
Minus(-)
1,701
Normal
1,890
Plus (+)
2,079
* @ .1" - .5" w.c. ESP
GMVM961155DX
(Rise Range: 35 - 65°F)
Adjust
CFM *
Tap
Minus(-)
1,629
Normal
1,810
Plus (+)
1,991
Minus(-)
1,665
Normal
1,850
Plus (+)
2,035
Minus(-)
1,701
Normal
1,890
Plus (+)
2,079
Minus(-)
1,746
Normal
1,940
Plus (+)
2,134
* @ .1" - .5" w.c. ESP
P
S
roduct
PecificationS
Rise (°F)
49
44
40
47
42
38
44
39
36
42
37
34
Rise (°F)
62
56
51
60
54
49
59
53
48
58
52
47