CLEARABLE
CLR WRNG
WARNINGS
PARALLEL I/F
SPEED
BI-DIRCT
I-PRIME
RS232C
FLOW CTL
SERIAL
BAUDRATE
DATABITS
PARITY
MIN BUSY
ON , JOB
Warning message appears when
printer must reconfigure memory to
select most efficient way to print a
complex job.
ON=Message displays, press
RECOVER to clear.
OFF=Message clears when next
print job is received.
HIGH , MEDIUM
HIGH=Data transfer speed
maximized.
MEDIUM=Select if data
transmission problems occur, or with
earlier
computers.
ENABLE ,
ENABLE=Select bi-directional
DISABLE
parallel communication.
OFF , ON
ON=I-Prime signal resets printer.
Set
OFF, or if HOST I/F is set to AUTO
IF, printer ignores signal.
DTR HI, DTR
Select serial protocol.
LO, XONXOFF,
RbstXON
9600 , 19200,
Select transmission rate in bits per
300, 600, 1200,
second (bps).
2400, 4800
8 BITS, 7 BITS
Select serial interface data bit
format.
NONE , EVEN,
Select serial interface parity type.
ODD
200 mSEC, 1
Set length of busy signal when
SEC
Ready/Busy (DTR) protocol is
selected.