(6) Horizontal Range
(7) Vertical Range
(8) E/S Range*
(9) E/S Shift*
(10) Offcenter
(11) TVG
(12) Clutter
(13) Elimination Interference
(14) Audio Monitor
*: Optional external E/S interface is required.
3. TRANSCEIVER
(1) Frequency
(2) Output Power
(3) Beamwidth
(4) Pulselength
4. HULL UNIT
(1) Train Step
(2) Tilting
Horizontal mode
Vertical Fan Mode
(3) Transducer Travel
(4) Raise/Lower Time
(5) Allowable Ship's Speed
5. POWER SUPPLY AND CONSUMPTION
(1) Display Unit
(2) Transceiver Unit
(3) Hull Unit
12 steps during 30 m to 1600 m
12 steps during 10 m to 800 m
5 steps during 10 m to 800 m
1000 m max.
4 point at Expand mode, according to the train setting
2 point at Slice mode, according to the tilt setting
Level(100 dB max.), Range(1000 m max.)
Variable, Hue control
Correlation with before data
2 W, 4 ohms using external speaker SC-05WR(option)
60/162 kHz selected by internal settings
0.8 kW(60 kHz), 1.5 kW(162 kHz)
-6 dB,
0.2 to 10.6 ms, varied according to the range in use
(selected on the Menu)
45° step by fast scan mode or 6° step by normal mode
Tilt Range: +5° to 90°, Tilt Step: 1° step
Tilt Range: 0° to +180°, Tilt Step: 6°(fast scan) or 3°(normal)
400 mm
10 sec approx. (24/32 VDC)
18 knots or less
(15 knots during raise/lower operation)
24/32 VDC (20 to 41.6VDC), 140 W approx. or
100/110/200/220 VAC, 50/60 Hz , 1
24/32 VDC (20 to 40 VDC), 50 W approx. or
100/110/200/220 VAC, 50/60 Hz , 1
24/32VDC, 50 W approx. (150 W while traveling)
AC spec. set requires rectifier RU-1746B-2
SP - 2