3. External control equipment (RS-422/485)
This is a terminal for connecting external control equipment.
The switch labeled TERM is used to turn ON/OFF terminating resistance for RS–422/485 communication
equipment.
PORT
PORT A
(Controller
SCC-3100A Control)
PORT B
(Speed Dome Control)
TERM 1 switch controls PORT A, TERM 2 Switch controls PORT B
1, 2 : ON → RS-485 MODE, OFF .→ RS-422 MODE
3, 4 : ON → Termination On, OFF → Termination Off
No.
RS-422
1
RX+ (+Data Receive)
2
RX- (-Data Receive)
3
N/C (Not connected)
4
N/C (Not connected)
5
GND(Ground)
6
N/C (Not connected)
7
Tx-(-Data Send)
8
Tx+(+Data Send)
9
Rx+(+Data Receive)
10
Rx-(-Data Receive)
11
N/C (Not connected)
12
N/C (Not connected)
13
GND(Ground)
14
N/C (Not connected)
15
Tx-(-Data Send)
16
Tx+(+Data Send)
SVR-1650E/1640A/950E User Manual
RS-485
Data+
Data-
N/C (Not connected)
N/C (Not connected)
GND(Ground)
N/C (Not connected)
Data-
Data+
Data+
Data-
N/C (Not connected)
N/C (Not connected)
GND(Ground)
N/C (Not connected)
Data-
Data+