Known Problems And Workarounds; Command Line Interface (Cli) - Avaya Cajun P550R Release Notes

V5.2.2
Hide thumbs Also See for Cajun P550R:
Table of Contents

Advertisement

Known Problems and Workarounds

ARP
Problem:
Workaround:
ATM Uplink Modules

Command Line Interface (CLI)

Flood Rate Limiting
Problem:
18
The following known problems and workarounds apply to Cajun
P550R, P580, P880, and P882 switches that are running switch
software, v5.2.2. If a known problem has a viable workaround, it
immediately follows the Problem statement. If the known problem
has no viable workaround, it is listed as a bulleted statement.
50-Series and 80-Series modules lose ARPs after you perform an
initialization of NVRAM (NVRAM init).
Reboot the switch twice after performing an NVRAM init.
The following problem has no workaround:
The 50-series ATM Uplink modules do not work in slot 16 or
slot 17 if you are using an 80-Series Supervisor module in a
Cajun P882 switch.
The following problem has no workaround
The "!" character, when used as part of a CLI command, is
considered a comment by the Cajun switch software:
If you type "!" BEFORE a CLI command, the switch
ignores the command and returns you to the CLI prompt.
If you type "!" after a CLI command, the switch displays
an Invalid Command or Syntax Error error message.
The options for setting flood rate limiting on 80-series, 10/100
Ethernet modules and on 80-series, 100 Base-FX Ethernet modules
are incorrect. The correct rates are not available from the Web Agent
or CLI.