Bosch D9000 Series Owner's Manual Supplement page 9

Table of Contents

Advertisement

7.
Press the [ENT] key to view the point's hardware state:
1PT### NORMAL HW if it is normal
1PT### SHORT HW if it is shorted
8.
Activate the point's sensor and observe the appropriate state
change.
9.
Press the [NEXT] key to advance to the next invisible point
within the scope of the keypad.
10.
Repeat steps 7 through 9 until all points are tested.
On a D1260 keypad with the Passcode Controlled Menu enabled:
1.
Press the [Menu>] soft key in the lower right corner.
2.
Press the [Next>] soft key until the Invisible Walk Test?
appears.
3.
Press the corresponding soft key to activate the Invisible
Walk Test function. The keypad shows the number of invisible
points within the scope of the keypad: ### points remain to be
tested.
Press the [View untested pts>] soft key to see 6 pts untested.
5.
6.
Press the [Next Pt>] soft key to view the first or next untested
point:
Area #, Pt #
[Point State] HW
<Exit
7.
Where [Point State] can be NORMAL,OPEN,SHORT, or MISSNG.
8.
Activate the point's sensor and observe the appropriate state
change.
9.
Repeat Steps 5 through 8 until all points are tested.
Bosch Security Systems | 5/05 | 33267F
D9000,G & GV2 Series | Owner's Manual Supplement
[Point Text]
1PT### OPEN HW if it is opened
1PT### MISSNG HW if it is missing
Next PT>
Prev PT>
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gv2 seriesD9412gv2D7412gv2D9000g seriesD9000gv2 series

Table of Contents