Lp Gas Only - Kenmore 153.336340 Owner's Manual

Mobile home gas water heater
Table of Contents

Advertisement

LP Gas Only
Liquefied petroleum gas is over 50% heavier than air and in the
occurrence of a leak in the system, the gas wilt settle at floor level.
Basements,
crawl spaces, skirted areas under mobile homes
(even when ventilated), closets and areas below ground level will
serve as pockets for the accumulation of gas. Before lighting an
L.R gas water heater, smell all around the appliance at floor level.
If you smell gas, follow the instructions as given in the warning on
the front page.
When your L.R tank runs out of fuel, turn off the gas at all gas
appliances
including pilot lights. After the tank is refilled, all
appliances
must be re-lit according to their
manufacturer's
instructions.
Explosion
Hazard
Have a qualified person make sure L.P. gas pressure
does not exceed 13" water column.
Examples of a qualified person include: licensed
plumbers, authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or
fire.
Table 1
Natural Gas Pipe Capacity
Table (Cu. Ft./Hr.)
Capacity of gas pipe of different diameters and lengths in cu. ft. per hr. with pressure drop of 0.3 in. and specific gravity
of 0.60 (natural gas).
Nominal Iron Pipe
Length of Pipe, Feet
Size, in.
10
20
30
40
50
60
70
80
90
100
125
150
175
200
1/2
132
92
73
63
56
50
46
43
40
38
34
31
28
26
3/4
278
190
152
130
115
105
96
90
84
79
72
64
59
55
1
520
350
285
245
215
195
180
170
160
150
130
120
110
100
1-1/4
1050
730
590
500
440
400
370
350
320
305
275
250
225
210
1-1/2
1600
1100
890
760
670
610
560
530
490
460
410
380
350
320
After the length of pipe has been determined, select the pipe size which will provide the minimum cubic feet per hour
required for the gas input rating of the water heater. By formula:
Gas Input of Water Heater
(BTU/HR)
Cu. Ft. Per Hr. Required=
Heating Value of Gas (BTU/FT 3)
The gas input of the water heater is marked on the water heater data plate. The heating value of the gas (BTU/FT 3)
may be determined by consulting the local natural gas utility.
Table 2
LP Gas Capacity
Table
Maximum capacityof pipe in thousands of BTU per hour of undilutedliquefied petroleumgases (at 11 inches water
column pressure). Based on a pressure drop of 0.5 inch water column.
Nominallron Pipe
Length ofPipe, Feet
Size,in.
10
20
30
40
50
60
70
80
90
100
125
150
1/2
275
189
152
129
114
103
96
89
83
78
69
63
3/4
576
393
315
267
237
217
196
185
173
162
146
132
1
1071
732
590
504
448
409
378
346
322
307
275
252
1-1/4
2205
1496
12t2
1039
913
834
771
724
677
630
567
511
Example:
Input BTU requirement of the water heater 100,000 BTUH.
Total pipe length, 80 feet = 3/4" IPS required.
Additional tables are available in the latest edition of the "National Fuel Gas Code", ANSI Z223.1.
18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.336444

Table of Contents