Piezoelectric
Igniter System
5
The piezoelectric
igniter system consists of the igniter button,
electrode, and wire.
The pilot is ignited by an electric spark
generated when the igniter button is pressed. The spark gap
of 0.125 inch is set when the electrode is installed at the factory.
(Figure 39). Use only factory authorized
piezoelectric
igniter
parts for replacement.
IGNITER
BUTTON
WIRE
TO
ELECTRODE
SNAP-ON
CONNECTOR
THERMOCOUPLE
/?P,LOT /
* NOTE: SPARK
GAP DISTANCE
MEASURED
FROM ELECTRODE
TIP TO PILOT.
FIGURE 39.
Testing the Igniter System
Turn off the gas to the water heater at the manual gas shut-off
valve. Watch the electrode tip while activating the igniter. A
visible spark should jump from the electrode. To avoid shock,
do not touch the burner or any metal part on the pilot or pilot
assembly.
If no spark is visible, check the wire connections
and make sure the electrode is not broken. Replace the igniter
if defective.
Dirt and rust on the pilot or electrode
tip can
prevent the igniter spark. Wipe clean with a damp cloth and dry
completely.
Rust can be removed from the electrode tip and
metal surfaces by lightly sanding with an emery cloth or fine
grit sandpaper.
Removing
and Replacing
the Gas Control
Valve/Thermostat
IMPORTANT: This water heater has a resettable thermal switch
installed.
Do not attempt to disable
or modify
this feature
in any way. Use only factory authorized
replacement
parts.
IMPORTANT: This gas control valve/thermostat
is shipped from
the factory as a natural gas unit. However, it may be converted
to use LP gas.
Before
installing
this gas control
valve/
thermostat,
make sure that it is configured for the type of gas
that you are using.
Refer to the "Gas Conversion" section.
Removing the Gas Valve:
1.
Turn off the gas supply to the water heater at the manual gas
shut-off valve. This valve is typically located beside the water
heater. Note the position of the shut-off valve in the open/on
position then proceed to turn it off (Figure 13).
2.
On the lower front of the water heater, locate the gas control
valve/thermostat
(see Figure 30). Before performing
any
maintenance,
it is important to turn the temperature dial on
the gas control valve/thermostat
to its lowest setting.
3.
On top of the gas control valve/thermostat,
turn the gas
control knob to the "OFF" position. See Lighting Instructions
on the water heater.
4.
Drain the water heater. Refer to the section of "Draining
and Flushing" section and follow the procedure.
33
6,
Disconnect
the igniter wire from the igniter, then remove
the igniter from the bracket by depressing the front and rear
holding tabs and lift. Next, remove the igniter bracket from
the gas valve. Disconnect
the thermocouple
(right-hand
threads), pilot tube, and manifold tube at the gas control
valve/thermostat
(Figure 29). Also disconnect the thermal
switch wires.
Refer to "Gas Piping" section (Figure 13) and disconnect
the ground joint union in the gas piping. Disconnect
the
remaining pipe from the gas control valve/thermostat.
To remove the gas control
valve/thermostat,
thread a
correctly sized pipe into the inlet and use it to turn the gas
control valve/thermostat
(counterclockwise.)
Do not use a
pipe wrench or equivalent to grip body. Damage may result,
causing leaks.
Do not insert any sharp objects into the inlet or outlet connections.
Damage to the gas control valve/thermostat may result.
Replacing the Gas Valve:
1.
To replace the gas control valve/thermostat,
reassemble
in reverse order. When replacing
the gas control valve/
thermostat, thread a correctly sized pipe into the inlet and
use it to turn the gas valve (clockwise.)
DO NOT OVER
TIGHTEN or damage may result. NOTE: Use an approved
TEFLON® tape or pipe compound
only on the threaded
section of the gas control valve/thermostat
that screws into
the tank.
2.
Reconnect
the gas
piping
to the
gas control
valve/
thermostat.
NOTE: Use an approved Teflon tape or pipe
compound on the gas piping connections.
3.
Attach the igniter and bracket to the new gas control valve/
thermostat, clipping it at the back edge of thermostat and
snapping it into place. NOTE: Do not use the (pilot) ferrule nut
supplied with the new gas control valve/thermostat,
unless
the existing nut is not usable. Reconnect the manifold tube,
pilot tube, thermocoupte,
igniter wire, and thermal switch
wires.
4.
Flit the tank completely
with water. NOTE: To purge the
lines of any excess air, keep the hot water faucet open
for 3 minutes after a constant flow of water is obtained.
5.
Turn on the gas supply and test the gas supply connections
by brushing on an approved noncorrosive
teak detection
solution. Bubbles forming indicate a leak. Correct any leak
found.
6.
Check the operation of the burner by following the lighting
instructions
on the front of the water heater. With the
burner tit, check the gas control valve/thermostat
supply
line, manifold tube and pilot tube connections for leaks.
7.
Verify proper operation and then replace the outer door.
8.
If additional information is required, contact Sears Service
at 1-800-4-MY-HOME
(1-800-469-4663).
TEFLON ® is a registered trademark of E.I. Du Pont De Nemours
and Company.
FVIR System Operational
Checklist
1.
Manifold gasket properly sealed.
2.
Viewport not damaged or cracked.
3.
Flame-arrestor free of debris and undamaged.
4.
Manifold component block properly installed.
5.
No leaks at pilot and manifold connection.
6.
Manifold door screws securely tightened.
7.
Depress the button on the thermal switch.