Troubleshooting Redundant Power Supplies - Dell PowerEdge 1600SC Systems Istallation And Troubleshooting Manual

Hide thumbs Also See for PowerEdge 1600SC:
Table of Contents

Advertisement

lasts longer). You may need to replace the battery if an incorrect time or date is displayed during the boot routine.
 
You can operate the system without a battery; however, the system configuration information maintained by the battery in NVRAM is erased each time you
remove power from the system. Therefore, you must re-enter the system configuration information and reset the options each time the system boots until you
replace the battery.
 
Action
1.  Re-enter the time and date through the System Setup program (see "Using the System Setup Program" in your User's Guide).
2.  Turn off the system and disconnect it from the electrical outlet for at least one hour.
3.  Reconnect the system to its electrical outlet and turn the system on.
4.  Enter the System Setup program.
 
If the date and time are not correct in the System Setup program, replace the battery (see
 
If the problem is not resolved by replacing the battery, see
 
NOTE:
Some software may cause the system time to speed up or slow down. If the system seems to operate normally except for the time kept in the
System Setup program, the problem may be caused by software rather than by a defective battery.
 
NOTE:
If the system is turned off for long periods of time (for weeks or months), the NVRAM may lose its system configuration information. This situation
is caused by a defective battery.
 

Troubleshooting Redundant Power Supplies

 
Problem
 Power indicator on the front panel does not light
l
 Power supply amber fault indicator is on
l
 Systems management software issues a power supply–related message
l
 No power to the system
l
 
Action
1.  Locate the faulty power supply.
 
The power supply's fault indicator is lit (see Figure 2-5).
2.  Check that a power cable is connected to the power supply and that the green AC line status indicator on the supply is lit (see
in "Indicators, Codes, and Messages)."
 
CAUTION:
To prevent risk of personal injury from electrical shock, do not reach into an empty power supply bay.
 
NOTICE:
The optional redundant power supplies are hot-pluggable. The system requires one power supply to be installed for the system to operate
normally. The system is in the redundant mode when two power supplies are installed. Remove and replace only one power supply at a time in a
system that is powered on.
3.  If AC power is available to the system, remove the faulty power supply (see
4.  Install a new power supply (see
 
NOTE:
After installing a new power supply, allow several seconds for the system to recognize the power supply and determine whether it is
working properly. The power supply status indicator will turn green if the power supply is functioning properly (see Figure 2-5).
5.  If the problem is not resolved, see
 
"Getting
"Installing a Redundant Power
Supply" in "Installing System Options").
"Getting
Help" for information on obtaining technical assistance.
"System
Battery" in "Installing System Options").
Help."
"Removing a Redundant Power
"Power Indicator
Supply" in "Installing System Options").
Codes"