SR-PC4

General
Power supply
19.5 V
Currnet consumption
5 A (with all options installed)
Operating temperature
5 °C to 35 °C (41 °F to 95 °F)
Storage temperature
–20 °C to +60 °C (–4 °F to +140 °F)
Mass
3.9 kg (8 lb. 10 oz.)
Dimensions
88 × 250 × 231 mm (3
1
9
/
protrusions)
Output connectors
MONITOR
BNC (1)
HD SDI (1.485 Gbps) (conforming to
SMPTE-292M, BTA-S004B)
3G SDI (2.97 Gbps) (SMPTE-424M)
NETWORK
1000Base-T modular jack (1)
Option
PCI Express Slot (1) (PCI Express x4
Gen1)
Supported formats
See "Supported Formats" on page 26.
On-board functions
1D LUT, downconverter, color space converter
Confirmed operational environment
Browser
Firefox, Internet Explorer, Safari, Google
Chrome
NFS server
Redhat Linux E5, Mac OS v10.6
CIFS server
Windows XP, Windows 7
Supplied accessories
AC adapter (1)
Rubber feet (4)
SR Viewer (CD-ROM) (1)
Installation manual (1)
Operation guide (1)
Operation manual (CD-ROM) (1)
Design and specifications are subject to change without
notice.
24

Appendix

1
7
/
× 9
/
2
8
in.) (W×H×D) (excluding
8
Appendix

Error/Warning Messages

When an abnormality is detected on the unit, a yellow
warning mark (
picture ID) in the MEM CONTROL window. Clicking the
warning mark displays the message as follows.
×
Error messages
Code Message
03
FAN STOP
04
POWER FAN
STOP
81
EPR PLD1 INITIAL
ERROR
82
EPR PLD2 INITIAL
ERROR
83
CN PLD1 INITIAL
ERROR
83
DC PLD1 INITIAL
ERROR
84
DM INTERFACE
ERROR
88
NVRAM
CHECKSUM
ERROR
) flashes to the left of the timecode (or
Description
A fan error was detected.
[PC5] An error was detected
with the fan located in the
power section.
[PC5] A PLD1 initialization error
was detected for the EPR-3
board.
[PC4] A PLD1 initialization error
was detected for the EPR-4
board.
[PC5] A PLD2 initialization error
was detected for the EPR-3
board.
[PC4] A PLD2 initialization error
was detected for the EPR-4
board.
[PC5] A PLD1 initialization error
was detected for the CN-3367
board.
[PC4] A PLD1 initialization error
was detected for the DC-161
board.
A communication error was
detected between the DM-145
and CPU.
An NVRAM (IC310) checksum
error was detected. IP address
and other configuration data
may be damaged.
Restart the unit using the
factory default settings
(IP address: 192.168.0.1;
subnet mask: 255.255.255.0;
MTU: 1500).