8.3

Management blades

Figure 49: management blade
The PRIMERGY BX900 S1 system unit has slots for two redundant, hot-swap
management blades with an integrated management solution for complete
remote administration of the system. The basic configuration of the BX900 S1
system unit contains one management blade.
The management blades offer user-friendly user interfaces: a Web interface
and a console menu interface via Telnet protocol. For a detailed description, see
the manual "PRIMERGY BX900 Blade Server Systems ServerView
Management Blade S1 User Interface Description".
The slots for the management blades are located on the back of the system unit
(see
figure 8 on page
A management blade is installed and removed in the same way as a connection
blade (see
"Installing a connection blade" on page
V
It is necessary to apply the firmware of the latest version to the
Management Blade in a Japanese market.
When two Management blades are installed, it is necessary to match the
versions of master/slave's Management blade firmwares.