Brocade Communications Systems PowerConnect B-FCXs Release Note page 47

Ironware software release r07.2.00a for brocade fesx, fsx, sx, fcx, fgs, fgs- stk, fls, fls-stk, and fws switches
Table of Contents

Advertisement

Defect ID: DEFECT000306952
Summary: Ports are removed from the running VLAN configuration.
Feature: FCX L2 Forwarding
Reported In Release: FI 07.1.00
Defect ID: DEFECT000307116
Summary: The FGS may reload when performing "write mem" when snmpv3 user profile is configured.
Feature: FCX Network Management
Reported In Release: FI 07.1.00
Defect ID: DEFECT000309028
Summary: Policy Based Routing may not forward correctly after ARPs age out or new ARPs are learned.
Feature: SX Layer 3 Forwarding - IPV4 and IPV6
Reported In Release: FI 07.1.00
Defect ID: DEFECT000311241
Summary: IPV6 management traffic is sent to an incorrect next hop.
Symptom: Unable to establish an IPV6 management session to the switch.
Probability: Low
Feature: SX Layer 3 Forwarding - IPV4 and IPV6
Reported In Release: FI 05.1.00
Defect ID: DEFECT000315402
Summary: No syslog or SNMP trap is sent if an external RPS2-EIF goes down.
Feature: SX Network Management
Reported In Release: FI 07.1.00
Defect ID: DEFECT000315930
Summary: Change of MSTP root bridge priority may cause long network convergence.
Feature: SX L2 Control
Reported In Release: FI 07.1.00
Defect ID: DEFECT000316883
Summary: Stack Master LED illuminates green even though it is running in standalone mode.
Symptom: In FLS running software version 4.3.03 or later, the Stack Master LED always illuminates
green even though it is running in standalone mode.
Probability: High
Feature: FCX Platform Specific features
Reported In Release: FI FGS 04.3.03
IronWare Software Release 07.2.00a for Brocade FastIron switches
Release Notes v 1.0
Technical Severity: High
Function: VLAN Manager
Technical Severity: Critical
Function: SNMP V4/V6
Technical Severity: High
Function: PBR
Technical Severity: High
Function: Data Forwarding
Service Request ID: 241304
Technical Severity: Medium
Function: SYSLOG
Technical Severity: Medium
Function: 802.1s
Technical Severity: Medium
Function: Chassis/fan/power
supplies/temperature sensors
Service Request ID: 259120
Page 47 of 55