At command completion (I/O registers contents to be read)
1F7
(ST)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(ER)
H
*1 If the command is terminated due to an error, the remaining number of
sectors of which data was not transferred is set in this register.
(9)
RECALIBRATE (X'1x', x: X'0' to X'F')
This command performs the calibration. Upon receipt of this command, the device sets BSY bit
of the Status register and performs a calibration. When the device completes the calibration, the
device updates the Status register, clears the BSY bit, and generates an interrupt.
This command can be issued in the LBA mode.
At command issuance (I/O registers setting contents)
1F7
(CM)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(FR)
H
At command completion (I/O registers contents to be read)
1F7
(ST)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(ER)
H
5 - 26
Status information
L
DV
End cylinder No. [MSB] / LBA
End cylinder No. [LSB] / LBA
End sector No.
00 (*1)
Error information
0
0
0
1
DV
xx
xx
xx
xx
xx
Status information
DV
xx
xx
xx
xx
Error information
C141-E112-01EN
End head No. /LBA [MSB]
/ LBA [LSB]
x
x
x
x
xx
xx