Fujitsu MPG3XXXAH Product Manual page 86

Fujitsu computer drive user manual
Table of Contents

Advertisement

Figure 5.1 shows an example of the execution of the READ MULTIPLE command.
Block count specified by SET MULTIPLE MODE command = 4 (number of sectors in a
block)
READ MULTIPLE command specifies;
Number of requested sectors = 9 (Sector Count register = 9)
Number of sectors in incomplete block = remainder of 9/4 =1
Command Issue
Parameter
Write
~
BSY
DRDY
INTRQ
DRQ
Sector
transferred
Figure 5.1
At command issuance (I/O registers setting contents)
1F7
(CM)
1
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(FR)
H
At command completion (I/O registers contents to be read)
1F7
(ST)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(ER)
H
*1 If the command is terminated due to an error, the remaining number of sectors for which data
was not transferred is set in this register.
Status read
1
2
3
4
Block
Execution example of READ MULTIPLE command
1
0
0
L
DV
Start head No. /LBA [MSB]
Start cylinder No. [MSB] / LBA
Start cylinder No. [LSB] / LBA
Start sector No.
Transfer sector count
xx
Status information
L
DV
End head No. /LBA [MSB]
End cylinder No. [MSB] / LBA
End cylinder No. [LSB] / LBA
End sector No.
00
(*1)
H
Error information
C141-E112-01EN
Status read
5
6
7
8
Block
0
1
0
0
/ LBA [LSB]
/ LBA [LSB]
Status read
9
Partial
block
5 - 19